6.- DESCRIPTION OF THE INPUTS AND OUTPUTS
6.1.- RF input
The RF input is through the RF
[35] connector on the side panel. The peak signal level should never exceed 130 dBµV.
6.2.- RS-232C serial port
The MTD 120 incorporates an RS-232C serial port for data exchange with a PC, a serial printer or to other devices. The signals in this
connector are described in Table 5.
Figure 34.- RS-232C connector. External view.
PIN No.
SIGNAL
CHARACTERISTICS
1
Carrier Detect
(not connected)
2
Data Request (RxD)
3
Data Transmit (TxD)
4
Data Transmission Ready (DTR)
Fixed at +12 V
5
Ground (GND)
6
Data Send Ready (DSR)
(not connected)
7
Request To Send (RTS)
8
Clear To Send (CTS)
9
Ring Indicator
(not connected)
Table 5.- Description of the RS-232C connector.