TV & SAT Level Meter MTD 120
User Manual
Figure 13.- DATALOGGER screen.
As you can see in the previous figure, the main screen of the Data logger function has three functions: Config (Configuration), Run and
Exit. Below these three functions is the measurements matrix, three columns and five rows are simultaneously displayed (in the previous
figure the data logger has three stored measurements, one for each of the first three memories).
To access the various screen functions or fields press key SHIFT [31] repeatedly.
4.9.2.4.1.- Configuring the Data Logger Function
The configuration menu of the Data logger function allows you to choose between taking and/or printing measurements, programming
the MTD 120 to take measurements at a pre-determined time, defining the time interval between measurements, erasing all measurements
stored in the Data logger function, and automatically deactivating all the measurement configurations.
To define the configuration of the Data logger function press key SHIFT [31] repeatedly until you have selected the Config field and then
press key ENTER [5]. The configuration screen of the Data logger function will then appear.
Figure 14.- Configuration of the DATA LOGGER function
After an interval of half a minute without the MTD 120 controls being touched, it will automatically return to the Data logger function main
screen.
1.- TO MEASURE, PRINT OR MEASURE AND PRINT?
First of all, the user must indicate whether he wants to take measurements or to print them, or to do both at the same time. To do this,
press key SHIFT [31] repeatedly until positioned in the Measure field. Then use keys
[6] to activate (On) or deactivate (Off) the
measurement function and press key SHIFT [31]. The next step is to activate or deactivate the measurement printing function. To do this, use
the key SHIFT [31] to position the cursor in the Print field and activate it (On) or deactivate it (Off) using keys
[6] and pressing key
ENTER [5] validate the new state.
2.- PROGRAMMING THE ALARM
To program the instrument to take measurements and/or print-outs at a specific time, you must define the time and date the
measurements are to be taken (Start acquisition time). If this field is not defined the acquisition of measurements will have to be activated
manually (see section '4.9.2.4.3 Taking Measurements'). When programming the alarm be sure to have checked that the date and time have
been correctly defined beforehand (Clock function, paragraph 4.9.2.5) and to have selected previously one measurement to be taken at
minimum (see section '4.9.2.4.2 Selecting the Measurements to be Taken').
To define the starting time of measurement acquisition repeatedly press key SHIFT [31] until the Start acquisition time field blinks, then
DATALOGGER
Measure: On
Print: Off
Start acquisition time:
.. : .. : .., .. / ..
Measure interval: 00 : 15
Clear
Unselect
DATALOGGER
•> Config
• Run
• Exit
1
2
3
1
49.8
55.2
53.4
2
...
...
...
3
...
...
...
4
...
...
...
5
...
...
...