113
ENGLISH
TV & SAT Level Meter MTD 120
User Manual
System & Standard
Selects the colour system (PAL, SECAM or NTSC) and the TV standard (B/G, D/K, I, L, M, N or Digital).
Battery & Lnb
Displays battery voltage and external units power supply voltage and current (V Lnb and I Lnb).
Data logger
Permits to acquire and to store up to 9801 measurements automatically.
Clock
Displays time and date, and allows them to be modified.
Input Video
Enables Scart commutation signals to be activated, deactivated or set to automatic/subordinate mode.
Channel set
Selects active channels table.
Units
Selects the measuring units: dBµV, dBmV or dBm.
Manual power
Sets power-off as Manual or Automatic.
C/N setup
Defines the C/N measuring method between Auto or Referenced.
Reference noise
(Only in C/N Reference noise mode). Defines the frequency where measure the noise level.
Channel BW
(Satellite band or digital channels). Defines channel bandwidth. Indispensable for measuring digital channels
and satellite band channel C/N.
Lnb local osc
(Only satellite band). It defines the frequency of the local oscillator (L.O.) of the LNB.
Video polarity
(Only satellite band, analogue channels). This selects the polarisation of the video carrier.
Nicam channel
(Only analogue channels). This selects the NICAM sound channel that is sent to the loudspeaker.
Search level
(Only analogue channels). Selects the threshold level of the automatic station search function.
Teletext
(Only analogue channels). Sets teletext information.
DiSEqC
(Only satellite channels). Defines a sequence of DiSEqC commands and permits to send them.
Beep
Activates (ON) / deactivates (OFF) the beeper.
Equipment info.
Displays information on the instrument: serial number, version of control software, options installed, etc.
Exit
Exits from the function menu.
In Spectrum Analyser mode the menu displays the following functions:
Band switching
Permits to switch from terrestrial (5-862 MHz) to satellite band (920-2150 MHz) and vice versa.
Span
Defines the frequency range displayed between Full (the entire band), 500 MHz, 200 MHz, 100 MHz, 50
MHz, 32 MHz, 16 MHz and 8 MHz (the latter two only for terrestrial bands).
Reference level
Defines the reference level between 70 and 130 dBµV in 10 dB steps.
Dual marker
(Only analogue channels, level measurement mode and single marker mode). Enables dual markers to be
shown on the displayed spectrum.
Marker A
(Only in dual marker mode). Selects marker A as the active marker (tuneable).
Marker B
(Only in dual marker mode). Selects marker B as the active marker (tuneable).
Single marker
(Only in dual marker mode). Activates the single marker on the displayed spectrum.
Sweep
Selects sweep speed in spectrum mode between Fast (fast sweep, low accuracy) and High Resolution
(slow sweep, high accuracy).
Reference noise
(Only in C/N measurements). Permits to define the frequency where noise level will be measured (see Carrier
function).
Channel bandwidth
(Only in Channel Power measurements). Permits to define channel bandwidth (see Marker function).
Marker
(Only when measuring Channel power and after defining the Channel bandwidth). Permits to change the
tuning frequency by means of the
keys.
Carrier
(Only when measuring C/N Referenced and after defining the Reference noise). Permits to change the tuning
frequency by means of the
keys.
Measure bandwidth
Selects the bandwidth of the spectrum measuring filter from among:
Terrestrial channels:
230 kHz or 1 MHz.
Satellite channels:
230 kHz or 4 MHz.
Channel set
Selects active channels table.
Battery & Lnb
Displays battery voltage and external units power supply voltage and current (V Lnb and I Lnb).
Exit
Exits from the function menu.