Place the fibre in the heads (250 μm on the black bracket 

and 900 μm on the blue bracket). The fibre should stick out 

around 3 or 4 cm.

 

Do not forget to put some heat-shrink tubing on one of 

the fibre ends before starting.

NOTE: 

You should swap heads with other machines. The 

fusion splicer is factory calibrated for heads with which 

it´s supplied, they are unique and interchangeable.

Follow these steps:

1. Strip and clean the fibre.

2. Introduce the head in the cleaver and cut the fibre.

3. Place the fibre head inside the fusion splicer.

4. Repeat steps 1,2 and 3 with the other fibre.

5. Shut the fibre clamp.

    

 

Both fibre ends should be visible on the screen:

If necessary, push the “RESET” button for the engines to go 

back to the starting point (should you not see the fibres co-

rrectly).

Now press “FUSE”. Fibres will get aligned and spliced. The 

whole  process  will  show  on  the  screen  in  around  10  se-

conds. (An automatic traction test will be carried out after 

fusion).

Finally, if the process was performed correctly, the splicer 

will display the estimated loss in dB, in green colour. If the 

process went wrong, the splicer may display either the esti-

mated loss in red colour or the message “Bad splicing”.

     

Hand-held fusion

Содержание 232130

Страница 1: ...trucciones w w w t e l e v e s c o m Hand held fusion splicer EN Operating instructions Fusionneuse de poche FR Manuel d utilisation Giuntatrice palmare IT Manuale d utilizzo Handsplei ger t DE Bedien...

Страница 2: ......

Страница 3: ...rmation 21 2 Fusion splicer 22 3 Keyboard 23 4 Use 23 5 Main menu 25 6 Configuration 27 7 Advice for the appropriate handling of fibre 30 8 Cleaning 32 9 SD Card 33 10 Specifications 33 Hand held fusi...

Страница 4: ...ot take the equip ment apart 4 Any errors in the external maintenance of the equip ment may cause fusion splicer malfunction or injuries to the maintenance operator carefully follow the mainte nance i...

Страница 5: ...er no circumstances shall Televes be held responsible for damages or harm of any nature that could derive from this manual or the information contained in it Composition Hand held fusion splicer Fibre...

Страница 6: ...22 2 Fusionadora 2 Fusion splicer Front view Top view Over SD card port Cover LCD screem USB port Cover Fibre clamp LCD screen keyboard Oven External changer connection Hand held fusion...

Страница 7: ...the unit for at least 6 to 8 hours before using it for the first time Once charged for the first time bear in mind that this equipment allows you to recharge the battery while in use Turn on the fusio...

Страница 8: ...fibre head inside the fusion splicer 4 Repeat steps 1 2 and 3 with the other fibre 5 Shut the fibre clamp Both fibre ends should be visible on the screen If necessary push the RESET button for the eng...

Страница 9: ...pushing the SELECTION button 5 1 Electrode cleaning Run the ELECTRODE CLEANING programme to get rid of dirt and impurities on the electrodes An additional elec tric arc will be produced to burn any re...

Страница 10: ...un the oven s program me The oven s programme is usually executed automati cally when a fusion is carried out see previous page Oven operation but under some circumstances you may wish to operate the...

Страница 11: ...6 2 Set time Adjust date and time with the UP and DOWN buttons To go through year month day etc press the MOVE button Once you are done with the adjustment select EXIT to exit this function and save...

Страница 12: ...rrect position see ima ge above the new position should be stored by pushing SELECTION on the SAVE option 6 6 Electrodes The ELECTRODES menu has the following options ADJUST In order to adjust the ele...

Страница 13: ...resent VERY IMPORTANT Activating this option increases bat tery consumption and reduces electrode working life The fusion splicer regularly warns about the need to clean the electrodes after 10 fusion...

Страница 14: ...nd 900 m fibre on the blue brackets See image Remember Not exchange heads between fusion split ters as previously indicated the fusion splitter is fac tory calibrated for heads supplied if they were e...

Страница 15: ...above shows a deviation of the fibre possibly due to bad fibre positioning or to a dirty V groove If the fibre is aligned correctly but not appropriately centred check section 6 5 Fibre position to c...

Страница 16: ...tioned method you can also clean the V groove with a cotton swab moistened with isopropyl alco hol Preferably combine both methods 8 2 Electrode cleaning The fusion splicer electrodes are sensitive an...

Страница 17: ...the fibre prior to fusion Loss estimation after fusion Indication of the cutting angle of each fibre Time required for the fusion operation 7 seconds Time required for the heat shrink tubing adjustmen...

Страница 18: ...televes com...

Отзывы: