Televes 232130 Скачать руководство пользователя страница 15

31

La fibra se cortará y obtendrá una fibra con un corte a 90º .

Abra la tapa y retire la fibra.

7.6 Placing the fibre

Put the cut and ready fibres in the splicer; to do so:

1.-  Open  the  fusion  splicer  main  cover  and  lift  the  fibre 

clamp.

2.  Introduce the fibre head into its track, leaning its front 

slightly to avoid the fibre hitting the V-groove, and place 

it over the latter.

(It should butt with the incorporated magnets; never force 

the brackets to bring the fibre in).

3.-Shut the fibre clamp, blocking the fibres.

4.- Shut the main cover. Fibres should now be visible in the 

screen, as shown below:

Correct

 

Incorrect

The image above shows a deviation of the fibre, possibly 

due to bad fibre positioning or to a dirty V- groove.

If the fibre is aligned correctly but not appropriately 

centred, check section 6.5, “Fibre position”, to calibrate its 

position.

Very bad

The image above shows one of the fibres is damaged, ba-

dly cut or dirty.

7.7 Fusing the fibre

To carry out the fusion, we need to make sure that we se-

lected  the  right  fusion  programme  in  the “SETTINGS”->” 

FIBRE SELECTION” menu, and then select the appropriate 

fibre. (See section 6.1, “Fibre selection”).

If both fibres look correct on the screen, push the fusion 

button;  automatically,  the  fibres  will  come  together,  the 

electric arc will be generated, and the fusion of the fibre 

will be done, as well as the traction test, and the estima-

tion of the loss in dB (Green colour = OK / Red colour = 

WRONG).

EN

Содержание 232130

Страница 1: ...trucciones w w w t e l e v e s c o m Hand held fusion splicer EN Operating instructions Fusionneuse de poche FR Manuel d utilisation Giuntatrice palmare IT Manuale d utilizzo Handsplei ger t DE Bedien...

Страница 2: ......

Страница 3: ...rmation 21 2 Fusion splicer 22 3 Keyboard 23 4 Use 23 5 Main menu 25 6 Configuration 27 7 Advice for the appropriate handling of fibre 30 8 Cleaning 32 9 SD Card 33 10 Specifications 33 Hand held fusi...

Страница 4: ...ot take the equip ment apart 4 Any errors in the external maintenance of the equip ment may cause fusion splicer malfunction or injuries to the maintenance operator carefully follow the mainte nance i...

Страница 5: ...er no circumstances shall Televes be held responsible for damages or harm of any nature that could derive from this manual or the information contained in it Composition Hand held fusion splicer Fibre...

Страница 6: ...22 2 Fusionadora 2 Fusion splicer Front view Top view Over SD card port Cover LCD screem USB port Cover Fibre clamp LCD screen keyboard Oven External changer connection Hand held fusion...

Страница 7: ...the unit for at least 6 to 8 hours before using it for the first time Once charged for the first time bear in mind that this equipment allows you to recharge the battery while in use Turn on the fusio...

Страница 8: ...fibre head inside the fusion splicer 4 Repeat steps 1 2 and 3 with the other fibre 5 Shut the fibre clamp Both fibre ends should be visible on the screen If necessary push the RESET button for the eng...

Страница 9: ...pushing the SELECTION button 5 1 Electrode cleaning Run the ELECTRODE CLEANING programme to get rid of dirt and impurities on the electrodes An additional elec tric arc will be produced to burn any re...

Страница 10: ...un the oven s program me The oven s programme is usually executed automati cally when a fusion is carried out see previous page Oven operation but under some circumstances you may wish to operate the...

Страница 11: ...6 2 Set time Adjust date and time with the UP and DOWN buttons To go through year month day etc press the MOVE button Once you are done with the adjustment select EXIT to exit this function and save...

Страница 12: ...rrect position see ima ge above the new position should be stored by pushing SELECTION on the SAVE option 6 6 Electrodes The ELECTRODES menu has the following options ADJUST In order to adjust the ele...

Страница 13: ...resent VERY IMPORTANT Activating this option increases bat tery consumption and reduces electrode working life The fusion splicer regularly warns about the need to clean the electrodes after 10 fusion...

Страница 14: ...nd 900 m fibre on the blue brackets See image Remember Not exchange heads between fusion split ters as previously indicated the fusion splitter is fac tory calibrated for heads supplied if they were e...

Страница 15: ...above shows a deviation of the fibre possibly due to bad fibre positioning or to a dirty V groove If the fibre is aligned correctly but not appropriately centred check section 6 5 Fibre position to c...

Страница 16: ...tioned method you can also clean the V groove with a cotton swab moistened with isopropyl alco hol Preferably combine both methods 8 2 Electrode cleaning The fusion splicer electrodes are sensitive an...

Страница 17: ...the fibre prior to fusion Loss estimation after fusion Indication of the cutting angle of each fibre Time required for the fusion operation 7 seconds Time required for the heat shrink tubing adjustmen...

Страница 18: ...televes com...

Отзывы: