WARNINGS

  Read this manual carefully before using the fusion splicer.

   Bear in mind that if you ignore the warnings or use the 

fusion splicer incorrectly, you may suffer from severe inju-

ries; this is why you should always follow the safety rules 

recommended for this equipment.

   Always use safety goggles when working with optical fi-

bre.

PRECAUTIONS

  The  charging  voltage  of  this  fusion  splicer  is  limited.

Always  use  the  power  supply  unit  provided  with  the 

equipment to charge the battery. The enclosed power 

supply unit is correctly set for a given input power (AC) 

and output power (DC); this is why you should not use 

any other values.

2

   Should the fusion splicer show any of the following ano-

malies:

 

- Weird smoke, smell or noise.

 

- Extreme heat.

 

-  Weird liquid or matter inside the equipment.

 

-  Breakdown or damage caused by falling o cras-

hing.

       You should immediately remove the power supply adap-

tor and turn the fusion splicer off, if it happened to be 

turned on. Then, contact Technical Support of Televes in 

order to proceed with its inspection or repair.

3

   Internal  manipulation  of  the  fusion  splicer  involves 

loosing  the  product  warranty  (do  not  take  the  equip-

ment apart).

4

   Any  errors  in  the  external  maintenance  of  the  equip-

ment may cause fusion splicer malfunction or injuries to 

the maintenance operator (carefully follow the mainte-

nance instructions).

5

   Never use the fusion splicer in the presence of flamma-

ble gases or liquids. Otherwise, it may lead to fires, ex-

plosions or other serious consequences.

  This fusion splicer is only used for optical fibre fusion, 

and should not be used for any other purposes.

  Do not expose the fusion splicer to high temperature 

or humidity.

  Avoid working in environments that are dusty or con-

tain airborne particles. This situation may cause failure 

in the fusion operations or damage to the equipment.

  Using the fusion splicer under different climatic condi-

tions (going from a cold to a warm environment, for ins-

tance)  may  generate  condensation  in  the  equipment. 

Wait for the condensation to completely disappear be-

fore working with it.

10 

  In order to keep the appropriate performance of the 

fusion splicer (based on the use that is made of it) we 

recommend to clean the equipment periodically.

11 

  The fusion splicer is calibrated in factory. Avoid strong 

vibrations or impacts, and use its own case for trans-

port and storage.

12 

  Due  to  the  high  complexity  of  this  equipment,  it 

should only be repaired by Televes.

Hand-held fusion

Содержание 232130

Страница 1: ...trucciones w w w t e l e v e s c o m Hand held fusion splicer EN Operating instructions Fusionneuse de poche FR Manuel d utilisation Giuntatrice palmare IT Manuale d utilizzo Handsplei ger t DE Bedien...

Страница 2: ......

Страница 3: ...rmation 21 2 Fusion splicer 22 3 Keyboard 23 4 Use 23 5 Main menu 25 6 Configuration 27 7 Advice for the appropriate handling of fibre 30 8 Cleaning 32 9 SD Card 33 10 Specifications 33 Hand held fusi...

Страница 4: ...ot take the equip ment apart 4 Any errors in the external maintenance of the equip ment may cause fusion splicer malfunction or injuries to the maintenance operator carefully follow the mainte nance i...

Страница 5: ...er no circumstances shall Televes be held responsible for damages or harm of any nature that could derive from this manual or the information contained in it Composition Hand held fusion splicer Fibre...

Страница 6: ...22 2 Fusionadora 2 Fusion splicer Front view Top view Over SD card port Cover LCD screem USB port Cover Fibre clamp LCD screen keyboard Oven External changer connection Hand held fusion...

Страница 7: ...the unit for at least 6 to 8 hours before using it for the first time Once charged for the first time bear in mind that this equipment allows you to recharge the battery while in use Turn on the fusio...

Страница 8: ...fibre head inside the fusion splicer 4 Repeat steps 1 2 and 3 with the other fibre 5 Shut the fibre clamp Both fibre ends should be visible on the screen If necessary push the RESET button for the eng...

Страница 9: ...pushing the SELECTION button 5 1 Electrode cleaning Run the ELECTRODE CLEANING programme to get rid of dirt and impurities on the electrodes An additional elec tric arc will be produced to burn any re...

Страница 10: ...un the oven s program me The oven s programme is usually executed automati cally when a fusion is carried out see previous page Oven operation but under some circumstances you may wish to operate the...

Страница 11: ...6 2 Set time Adjust date and time with the UP and DOWN buttons To go through year month day etc press the MOVE button Once you are done with the adjustment select EXIT to exit this function and save...

Страница 12: ...rrect position see ima ge above the new position should be stored by pushing SELECTION on the SAVE option 6 6 Electrodes The ELECTRODES menu has the following options ADJUST In order to adjust the ele...

Страница 13: ...resent VERY IMPORTANT Activating this option increases bat tery consumption and reduces electrode working life The fusion splicer regularly warns about the need to clean the electrodes after 10 fusion...

Страница 14: ...nd 900 m fibre on the blue brackets See image Remember Not exchange heads between fusion split ters as previously indicated the fusion splitter is fac tory calibrated for heads supplied if they were e...

Страница 15: ...above shows a deviation of the fibre possibly due to bad fibre positioning or to a dirty V groove If the fibre is aligned correctly but not appropriately centred check section 6 5 Fibre position to c...

Страница 16: ...tioned method you can also clean the V groove with a cotton swab moistened with isopropyl alco hol Preferably combine both methods 8 2 Electrode cleaning The fusion splicer electrodes are sensitive an...

Страница 17: ...the fibre prior to fusion Loss estimation after fusion Indication of the cutting angle of each fibre Time required for the fusion operation 7 seconds Time required for the heat shrink tubing adjustmen...

Страница 18: ...televes com...

Отзывы: