Televes 232130 Скачать руководство пользователя страница 17

33

9. SD Card 

It allows the downloading of the values extracted for each fu-

sion to the card (provided the card is inserted). The values can 

thus be read or extracted into a PC later on.

10. Specifications

  Manufactured in Europe.
   Accepted fibre types: SM (9/125 micron, with 250-micron or 

900-micron protection), MM (50/125 micron and 62.5/125 mi-

cron).

     Fusion and oven capacity (per battery charge):

   +/- 60.

    Fusion modes: 2. Predefined (Single-mode (SM) and multimo-

de (MM) fibre).

 

  

Fibre alignment: Cladding alignment.

    Typical loss after fusion:

  SM 0.03 dB /MM 0.01 dB.

    Detection of possible anomalies in the fibre (prior to fusion).

    Loss estimation (after fusion).

    Indication of the cutting angle of each fibre.

  Time required for the fusion operation: 7 seconds.
   Time required for the heat-shrink tubing adjustment (35 se-

conds for 45-mm, and 60 seconds for 60-mm tubes).

  Equipment languages: ES-EN-DE-IT-FR-SV-CS-TR-PL-NL-RU.

  Interfaces:

                Mini USB (for possible upgrades).
                 SD-Extreme  (not  included)  for  the  recording  and  ex-

traction of the parameters used in the fusion operation.

  Lens magnification: 140X.

  Colour LCD screen, 2.8”, 320 x 240 pixels.
   Equipment dimensions: 230 mm (height) x 98 mm (width) x 

54 mm (depth).

  Weight: 0.8 kg.

  7.4V, 3000 mA battery (Li-Ion).
   External power supply unit: 6V, 1.5A, 100-240V AC / 50-60 Hz.
   Work environment: From 0 oC to 45 oC / 95% Maximum relati-

ve humidity (with no condensation).

EN

Содержание 232130

Страница 1: ...trucciones w w w t e l e v e s c o m Hand held fusion splicer EN Operating instructions Fusionneuse de poche FR Manuel d utilisation Giuntatrice palmare IT Manuale d utilizzo Handsplei ger t DE Bedien...

Страница 2: ......

Страница 3: ...rmation 21 2 Fusion splicer 22 3 Keyboard 23 4 Use 23 5 Main menu 25 6 Configuration 27 7 Advice for the appropriate handling of fibre 30 8 Cleaning 32 9 SD Card 33 10 Specifications 33 Hand held fusi...

Страница 4: ...ot take the equip ment apart 4 Any errors in the external maintenance of the equip ment may cause fusion splicer malfunction or injuries to the maintenance operator carefully follow the mainte nance i...

Страница 5: ...er no circumstances shall Televes be held responsible for damages or harm of any nature that could derive from this manual or the information contained in it Composition Hand held fusion splicer Fibre...

Страница 6: ...22 2 Fusionadora 2 Fusion splicer Front view Top view Over SD card port Cover LCD screem USB port Cover Fibre clamp LCD screen keyboard Oven External changer connection Hand held fusion...

Страница 7: ...the unit for at least 6 to 8 hours before using it for the first time Once charged for the first time bear in mind that this equipment allows you to recharge the battery while in use Turn on the fusio...

Страница 8: ...fibre head inside the fusion splicer 4 Repeat steps 1 2 and 3 with the other fibre 5 Shut the fibre clamp Both fibre ends should be visible on the screen If necessary push the RESET button for the eng...

Страница 9: ...pushing the SELECTION button 5 1 Electrode cleaning Run the ELECTRODE CLEANING programme to get rid of dirt and impurities on the electrodes An additional elec tric arc will be produced to burn any re...

Страница 10: ...un the oven s program me The oven s programme is usually executed automati cally when a fusion is carried out see previous page Oven operation but under some circumstances you may wish to operate the...

Страница 11: ...6 2 Set time Adjust date and time with the UP and DOWN buttons To go through year month day etc press the MOVE button Once you are done with the adjustment select EXIT to exit this function and save...

Страница 12: ...rrect position see ima ge above the new position should be stored by pushing SELECTION on the SAVE option 6 6 Electrodes The ELECTRODES menu has the following options ADJUST In order to adjust the ele...

Страница 13: ...resent VERY IMPORTANT Activating this option increases bat tery consumption and reduces electrode working life The fusion splicer regularly warns about the need to clean the electrodes after 10 fusion...

Страница 14: ...nd 900 m fibre on the blue brackets See image Remember Not exchange heads between fusion split ters as previously indicated the fusion splitter is fac tory calibrated for heads supplied if they were e...

Страница 15: ...above shows a deviation of the fibre possibly due to bad fibre positioning or to a dirty V groove If the fibre is aligned correctly but not appropriately centred check section 6 5 Fibre position to c...

Страница 16: ...tioned method you can also clean the V groove with a cotton swab moistened with isopropyl alco hol Preferably combine both methods 8 2 Electrode cleaning The fusion splicer electrodes are sensitive an...

Страница 17: ...the fibre prior to fusion Loss estimation after fusion Indication of the cutting angle of each fibre Time required for the fusion operation 7 seconds Time required for the heat shrink tubing adjustmen...

Страница 18: ...televes com...

Отзывы: