User Guide -
EZMesh Full Duplex Mesh Network Access Point
Setup Trunk and Native VLAN Mode
Step 1. Login
to the
Ethernet/VLAN
Step 2.
Check
“Trunk and Native VLAN” radio button under the
VLAN Ethernet
Mode
Step 3.
Click
Save Setting and Apply
Pure Mode
Pure Trunk - Only tagged (VLAN IDs and priority included) frames entering the
Ethernet port will be accepted. Egress frames will exit the Ethernet port unaltered.
If the frame leaving the Ethernet port contains a VLAN tag, it will be transmitted
with that same tag. If the frame leaving the Ethernet port does not contain a VLAN
tag, the frame with be transmitted without a tag. In this mode, the MeshAP must
be connected to a VLAN capable device and the port on that device must be
configured as a Trunk port.
Setup Pure Mode
Step 1. Login
to the
Ethernet/VLAN
Step 2.
Check
“Pure” radio button under the
VLAN Ethernet Mode