RESET Parameters
29
TeleTek
CA60Plus
Installation Manual
APPENDIX A
RESET Parameters Table
PROGRAM MENU
ADDRESS
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LOOP TYPE
10
DUAL - LED1 to LED6 do not light
ALARM - LED1 to LED6 light
ZONE 1
11
!
Entry/Exit
ALARM
PANIC
TAMPER
FIRE
MEDICAL
ATTRIBUTES ZONE 1
"
FOLLOW
DOUBLE
PART1
PART2
CHIME
FAST
ZONE 2
12
!
Entry/Exit
ALARM
PANIC
TAMPER
FIRE
MEDICAL
ATTRIBUTES ZONE 2
"
FOLLOW
DOUBLE
PART1
PART2
CHIME
FAST
ZONE 3
13
!
Entry/Exit
ALARM
PANIC
TAMPER
FIRE
MEDICAL
ATTRIBUTES ZONE 3
"
FOLLOW
DOUBLE
PART1
PART2
CHIME
FAST
ZONE 4
14
!
Entry/Exit
ALARM
PANIC
TAMPER
FIRE
MEDICAL
ATTRIBUTES ZONE 4
"
FOLLOW
DOUBLE
PART1
PART2
CHIME
FAST
ZONE 5
15
!
Entry/Exit
ALARM
PANIC
TAMPER
FIRE
MEDICAL
ATTRIBUTES ZONE 5
"
FOLLOW
DOUBLE
PART1
PART2
CHIME
FAST
ZONE 6
16
!
Entry/Exit
ALARM
PANIC
TAMPER
FIRE
MEDICAL
ATTRIBUTES ZONE 6
"
FOLLOW
DOUBLE
PART1
PART2
CHIME
FAST
PGM 1
21
!
ALARM
PANIC
TAMPER
FIRE
FIRE/RST
ON/OFF
"
MEDICAL PS/bypass
AC LOSS
BAT LOW
FUSE
Pol+ / -
PGM 2
22
!
ALARM
PANIC
TAMPER
FIRE
FIRE/RST
ON/OFF
"
MEDICAL PS/bypass
AC LOSS
BAT LOW
FUSE
Pol+ / -
PGM 3
23
!
ALARM
PANIC
TAMPER
FIRE
FIRE/RST
ON/OFF
"
MEDICAL PS/bypass
AC LOSS
BAT LOW
FUSE
Pol+ / -
SIREN OUTPUT
24
ALARM
PANIC
TAMPER FIRE/ALW
EXIT TIME
30
0-9 SEC
10-19 SEC 20-29 SEC 30-39 SEC 40-49 SEC 50 - 59 SEC
ENTRY TIME
31
0-9 SEC
10-19 SEC 20-29 SEC 30-39 SEC 40-49 SEC 50 - 59 SEC
BELL TIME
32
1 MIN
2 MIN
3 MIN
4 MIN
5 MIN
6 MIN
BELL DELAY
33
1 MIN
2 MIN
3 MIN
4 MIN
5 MIN
6 MIN
SET WITH CODE
40
NO - LED1 to LED6 do not light
YES - LED1 to LED6 light
USER CODE 1
41
UNSET
FULSET PARTSET1 PARTSET2
LOG
BYPASS
USER CODE 2
42
UNSET
FULSET PARTSET1 PARTSET2
LOG
BYPASS
USER CODE 3
43
UNSET
FULSET PARTSET1 PARTSET2
LOG
BYPASS
USER CODE 4
44
UNSET
FULSET PARTSET1 PARTSET2
LOG
BYPASS
USER CODE 5
45
UNSET
FULSET PARTSET1 PARTSET2
LOG
BYPASS
USER CODE 6
46
UNSET
FULSET PARTSET1 PARTSET2
LOG
BYPASS
MANGER ACCESS
47
NO - LED1 to LED6 do not light
YES - LED1 to LED6 light
ENGINEER CODE
50
DIGIT 1
DIGIT 2
DIGIT 3
DIGIT 4
RESET ENABLE
51
NO - LED1 to LED6 do not light
YES - LED1 to LED6 light
DEFAULT SETTINGS
52
Press the keys from 1 to 6 consequently and confirm by ENTER
PART. RESET
53
Press the keys from 1 to 6 consequently and confirm by ENTER
54 to 89 address indication, concerning the communicator parameters, is hexadecimal, the LEDs 3,4,5,6 are
used (Lower BIT - LED 6)
TEL No PC FOR UDL
PC ID FOR UDL
PANEL ID FOR UDL
CALL BACK
NO - LED1 to LED6 do not light
YES - LED1 to LED6 light
No OF RINGS
ANSW. MACHINE
NO - LED1 to LED6 do not light
YES - LED1 to LED6 light
TEL No 1
60
Max phone number lenght 16 symbols, pause=ON+2, DTMF =ON+1
PANEL ID 1
61
3 or 4 digits (depending on the report 3
х
or 4
х
)
REPORT 1
62
The report number included in the applied table is entered
х
1/
х
2
63
x2 - LED1 to LED6 do not light
x1 - LED1 to LED6 light
TEL No 2
64
Max phone number lenght 16 symbols, pause=ON+2, DTMF =ON+1
PANEL ID 2
65
3 or 4 digits (depending on the report 3
х
or 4
х
)
REPORT 2
66
The report number included in the applied table is entered
х
1/
х
2
67
x2 - LED1 to LED6 do not light
x1 - LED1 to LED6 light
WAIT DIAL TONE
68
NO - LED1 to LED6 do not light
YES - LED1 to LED6 light
59
4 digits. Default 1234
4 digits. Default 1234
Max phone number lenght 16 symbols, pause=ON+2, DTMF =ON+1
1 digit. (0 to 9)
56
57
58
54
55