7. COMMUNICATOR TEST PARAMETERS

ADDRESS 70

SYSTEM CLOCK SETTINGS

CLOCK

In this address the hour and minutes are set (HH:MM). The indication is
hexadecimal and the digits show up one by one. The digits are monitored by the
arrow keys.

DEFAULT

 : 

00:00 h

ADDRESS 71

TEST REPORT TIME

TEST TIME

In this address the hour for transmission the test message to the monitoring
station is chosen. Hour and minutes are set (HH:MM). Hexadecimal indication.

DEFAULT

 : 

14:01 h

ADDRESS 72

AUTO REPORTING

TEST PERIOD

In this address the period for test message transmission is set in days (DD).
Hexadecimal indication. 

Two digit numbers should be used. When a period

less than 10 days is chosen the first digit should be 0.

DEFAULT

 : 

01 day

ADDRESS 73

TEST REPORT CODE

TEST CODE

The first symbol of the “test report” event code is set (X). The panel transmits
as a second symbol a copy of the first. Hexadecimal indication.

DEFAULT

 : 

A

ADDRESS 74

LINE FAULT INDICATION DELAY

LF DELAY

Delay time in minutes (MM) before the indication for LF is set. Hexadecimal
indication. 

Two digit numbers should be used. When a period lesser than

10 minutes is chosen the first digit should be 0. If an indication for LF is
not necessary, 00 should be entered.

DEFAULT

 : 

00 minutes

25

TeleTek

CA60Plus

Installation Manual

Содержание CA60Plus

Страница 1: ...TeleTek CA60Plus Software version 3 1 Installation Manual May 2000...

Страница 2: ...mable Output SIREN 7 7 Detectors Wiring 9 8 Internal Communicator Wiring 10 9 Powering up the Panel 10 PART II Programming the CA60Plus Parameters 11 1 Zone Configuration 14 2 PGM and SIREN programmab...

Страница 3: ...rate electromagnetic noise 4 1 Use relays with good isolation between the contacts and the coil 4 2 The relays connected to outputs with an open collector should be designed for 12 V DC and coil imped...

Страница 4: ...Mounting holes 2 CA60Plus Security Panel 3 AC terminal 4 Signal cables holes 5 AC cable hole 1 Fig 1 CA60Plus Security Control Panel Transmitter Ca60Plus Fig 2 CA60Plus LED Display Keypad a Cover 1 2...

Страница 5: ...d A and B to telephone company connectors A1 and B1 to phone RED and BLACK keypad power supply GREEN and YELLOW panel keypad interface F1 battery fuse 2A F2 auxilliary supply fuse 1A F3 fuse 1A for po...

Страница 6: ...mpers JT the first keypad address J0 the second keypad address J1 the third keypad address If there is only one keypad in the security panel it is obligatory that the JT jumper is installed When more...

Страница 7: ...Output SIREN The SIREN output of the control panel is designed for siren managing A managing signal toward a siren with blocking input could be generated or power supply managed siren provided The tw...

Страница 8: ...ing Two managing signals are used SIREN and PGM3 When an alarm event occurs the SIREN output switches to a low level and activates the SR2000 siren When an alarm event responding to the PGM3 parameter...

Страница 9: ...rogrammed By default the balancing is ALARM type On Fig 9 a b and c are described the possible variants of wiring the detectors and balancing the zones 9 TeleTek CA60Plus InstallationManual 1k NC RELA...

Страница 10: ...he security panel through the RED and the BLACK cable The normal condition of the security panel all the detectors are non active and there are no troubled TAMPER circuits is indicated on the keypad b...

Страница 11: ...el configuration after RESET All the possible parameters the indication on the keypad display and the necessary manipulations for programming are described in details for each separate address The dat...

Страница 12: ...TAMPER FIRE FIRE RST ON OFF 1 2 3 4 5 1 min 2 min 3 min 4 min 5 min 6 6 min 1 2 3 4 5 0 1 min 2 min 3 min 4 min 5 min 0 min 6 6 min 0 Balancing 1 2 3 4 5 6 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 E...

Страница 13: ...r 2 Subscriber Account 2 Communication Report 1 Report Format 2 Phone Number 1 Subscriber Account 1 Report Format 1 Communication Report 2 Wait Dial Tone 8 Communicator Event Codes 9 4 5 8 7 6 MEDICAL...

Страница 14: ...3 PANIC 24 hour Panic zone 4 TAMPER 24 hour Tamper zone 5 FIRE 24 hour Fire zone 6 MEDICAL 24 hour Medical zone ZONE 1 ATTRIBUTES SUBMENU In this submenu the attributes for ZONE 1 are chosen The zone...

Страница 15: ...he MEMORY LED and the zone LED illuminate constantly The memory is erased either by reentering a valid user code or when the system is armed again Audible Panic activates the PGMs and the SIREN output...

Страница 16: ...ivation is ignored If the zone remains active for more than 15 sec the alarm starts immediately PART1 Zone with PART1 attribute enters Partial Security Mode PART SET1 The zones with no such attribute...

Страница 17: ...re activated regardless the status of the system armed or disarmed The output is restored when the tamper is restored 4 FIRE Activated when a FIRE type zone is activated The output is restored by ente...

Страница 18: ...user or master code or automatically after the bell time is expired TAMPER Activated when the tamper of a zone or a TAMPER type zone are activated regardless the status of the system armed or disarme...

Страница 19: ...d less than 10 sec the first digit should be 0 The lighting scale formed by the LEDs from 1 to 6 indicates the period Each lighting LED includes 10 seconds For example if the LEDs 1 2 and 3 light the...

Страница 20: ...nables this user code to arm the area 3 Part Set 1 Enables this user code to arm PART1 of the area 4 Part Set 2 Enables this user code to arm PART2 of the area 5 Log Gives this user code an access rig...

Страница 21: ...4 5 6 keys are MANAGER CODE pressed in sequence and confirmed by ENTER The system recharges the default manager code ADDRESS54 PHONE NUMBER FOR REMOTE PROGRAMMING Tel No for In this address the phone...

Страница 22: ...mote programming is set NUMBER OF The symbols from 0 to 9 could be used RINGS If 0 entered the remote programming is disabled It is recommended to enter value up to 7 DEFAULT 7 ADDRESS59 ANSWERINGMACH...

Страница 23: ...e monitoring station are listed in the table REPORT 1 below The symbols from 0 to B could be used 0 User report dialer 1 SP 10 pps HS KO 1400Hz Data 1900Hz 3x1 3x2 4x1 4x2 2 SP 10 pps HS KO 1400Hz Dat...

Страница 24: ...1 3x2 4x1 4x2 4 SP 20 pps HS KO 1400Hz Data 1900Hz EXT 3x1 4x1 5 SP 20 pps HS KO 2300Hz Data 1800Hz 3x1 3x2 4x1 4x2 6 SP 20 pps HS KO 2300Hz Data 1800Hz EXT 3x1 4x1 7 SP 40 pps HS KO 2300Hz Data 1800H...

Страница 25: ...sage transmission is set in days DD Hexadecimal indication Two digit numbers should be used When a period less than 10 days is chosen the first digit should be 0 DEFAULT 01 day ADDRESS73 TESTREPORTCOD...

Страница 26: ...e message to the monitoring station DEFAULT 2 ADDRESS82 TAMPERREPORTCODE TAMPER CODE TAMPER Report Code X Hexadecimal indication The zone number is automatically added before sending the message to th...

Страница 27: ...E TROUBLE CODE Trouble Report code X Hexadecimal indication The number of the respective trouble is added automatically before transmitting the message to the monitoring station as follows x1 Blown Fu...

Страница 28: ...rom the communicator to the monitoring station Pressing the 0 key interrupts the current communication and erases the non transmitted events To exit the address press CLEAR The LEDs indication is as f...

Страница 29: ...CODE 1 41 UNSET FULSET PARTSET1 PARTSET2 LOG BYPASS USER CODE 2 42 UNSET FULSET PARTSET1 PARTSET2 LOG BYPASS USER CODE 3 43 UNSET FULSET PARTSET1 PARTSET2 LOG BYPASS USER CODE 4 44 UNSET FULSET PARTSE...

Страница 30: ...TAMPER Report code RESET Value 3 FIRE CODE 83 FIRE Report code RESET Value 4 MEDICAL CODE 84 MEDICAL Report code RESET Value 5 BYPASS CODE 85 BYPASS Report code RESET Value 6 ON CODE 86 ON Report code...

Страница 31: ...ET2 LOG BYPASS USER CODE 3 13 UNSET FULSET PARTSET1 PARTSET2 LOG BYPASS USER CODE 4 14 UNSET FULSET PARTSET1 PARTSET2 LOG BYPASS USER CODE 5 15 UNSET FULSET PARTSET1 PARTSET2 LOG BYPASS USER CODE 6 16...

Страница 32: ...e to causes beyond the control of TeleTek Ltd such as lighting excessive voltage mechanical shock or water damage LIABILITY Under no circumstances shall TeleTek Ltd be held liable for any direct or in...

Отзывы: