4. CODE SYSTEM MANAGEMENT
ADDRESS 40
SET WITH CODE
NO
Full or Partial arming of the area does not require confirmation by entering a
valid user code. The LEDs from 1 to 6 do not light.
YES
Full or Partial arming of the area requires confirmation by entering a valid user
code. The LEDs from 1 to 6 light.
DEFAULT
:
NO
ADDRESS 41
USER CODE 1 ATTRIBUTES
In this address the USER CODE1 attributes are set. The user code could have
more than one attribute. An attribute is activated/desactivated alternately by
pressing the digit of the respective number. The choice is indicated by lighting of
the LED with the number of the pressed digit. At the end of the procedure on
the display should light only the LEDs responding to the desired attributes.
1 Unset
Enables this user code to disarm the area.
2 FullSet
Enables this user code to arm the area.
3 Part Set 1
Enables this user code to arm PART1 of the area.
4 Part Set 2
Enables this user code to arm PART2 of the area.
5 Log
Gives this user code an access right to the event memory.
6 Bypass
Gives this user code a right to bypass zones in the secured area.
DEFAULT
:
UNSET, FULLSET, PART SET1, PART SET2, LOG, BYPASS
ADDRESS 42
USER CODE 2 ATTRIBUTES
Programming as in address 41.
DEFAULT
:
No
ADDRESS 43
USER CODE 3 ATTRIBUTES
Programming as in address 41.
DEFAULT
:
No
ADDRESS 44
USER CODE 4 ATTRIBUTES
Programming as in address 41.
DEFAULT
:
No
ADDRESS 45
USER CODE 5 ATTRIBUTES
Programming as in address 41.
DEFAUL]T
:
No
ADDRESS 46
USER CODE 6 ATTRIBUTES
Programming as in address 41.
DEFAULT
:
No
ADDRESS 47
MANAGER ACCESS TO THE USER CODE ATTRIBUTES
NO
The access of the manager to the user codes rights is denied.
The LEDs from 1 to 6 do not light.
YES
The access of the manager to the user codes rights is allowed.
The LEDs from 1 to 6 light.
DEFAULT
:
YES
20
TeleTek
CA60Plus
Installation Manual