8. COMMUNICATOR EVENT CODES
For the Report Codes only the first symbol should be entered. The second is
automatically generated by the security panel.
If the symbol 0 is entered as a code, the respective event will not be transmitted
by the communicator.
Consult your Monitoring company about the event codes.
ADDRESS 80
ALARM REPORT CODE
ALARM CODE
ALARM Report Code (X). Hexadecimal indication. The zone number is
automatically added before sending the message to the monitoring station.
DEFAULT
:
1
ADDRESS 81
PANIC REPORT CODE
PANIC CODE
PANIC Report Code (X). Hexadecimal indication. The zone number is
automatically added before sending the message to the monitoring station.
DEFAULT
:
2
ADDRESS 82
TAMPER REPORT CODE
TAMPER CODE
TAMPER Report Code (X). Hexadecimal indication. The zone number is
automatically added before sending the message to the monitoring station.
DEFAULT
:
3
ADDRESS 83
FIRE REPORT CODE
FIRE CODE
FIRE Report Code (X). Hexadecimal indication. The zone number is
automatically added before sending the message to the monitoring station.
DEFAULT
:
4
ADDRESS 84
MEDICAL REPORT CODE
MEDICAL CODE
MEDICAL Report Code (X). Hexadecimal indication. The zone number is
automatically added before sending the message to the monitoring station.
DEFAULT
:
5
ADDRESS 85
BYPASS REPORT CODE
BYPASS CODE
BYPASS Report Code (X). Hexadecimal indication. The zone number is
automatically added before sending the message to the monitoring station.
DEFAULT
:
6
26
TeleTek
CA60Plus
Installation Manual