Management Connection
The Mgmt (Management) connector provides one bi-directional data
channel (RS232). The Mgmt connection is meant for confi guration
and controlling of BLUEbox devices locally by CLI. Management
connection between BLUEbox devices and e.g. laptop is based on a
serial data communication by means of any terminal type program
(e.g Windows Hyper Terminal). Management software for BLUEbox
devices is a Command Line Interface (see page 21 for detailed
description). The Mgmt connector is type RJ-45 female (see picture
6 and table 3 for detailed description). The management cable is
type CIC504 (see table 7 on page 8 for pinouts).
Picture 6.
Management connector.
Table 3.
Mgmt connector’s pinout.
Pin
Signal
1
2
Mgmt
out
3
4
5
Ground
6
Mgmt
in
7
8
Ground
6
BLUEbox series user manual rev002