4
Configuration
Page 39
CELLX box 17.1/002
4.6.5
Configuration files for VoIP scenarios
These files are designed for the failover and cost saving model scenarios using VoIP connec-
tions. Possible changes of the
ip.cfg
are not shown in this chapter.
If you want to use either of these VoIP scenarios with the CELLX Box, rename the config files
pabx.cfg and
route.cfg
and adjust them to suit your needs. The adjustments are described
in more detail in
Chapter 5 "Adapting the config files" on page 43
. They are described in
brief here.
The pabx.cfg shown in
Example 4.11
differs from the pabx.cfg shown in
Example 4.2 on
page 31
in three points described below.
Example 4.11
pabx.cfg for failover and other VoIP scenarios
[System]
PABXName=CELLX_GSM-4_FXS-4 ; (1)
NameServer=8.8.8.8 ;
NtpServer=pool.ntp.org
Timezone=CET-1CEST-2,M3.5.0/02:00:00,M10.5.0/03:00:00 ; Central European Time
ActionLog=/boot/protocol.log weekly 1200 3
TraceLog=/boot/trace.log daily 900 7
MsgLog=/boot/msg.log weekly 1200 3
Failedlog=/boot/failed.log daily 1200 7
Log=/boot/cdr.log daily 1200 7 ; (3)
StatisticTime=/boot/asr.log 00:00 11111111
Controller00=10 FXS
Controller01=11 FXS
Controller02=12 FXS
Controller03=13 FXS
Controller04=20 GSM ; (2)
Controller05=20 GSM
Controller06=20 GSM
Controller07=20 GSM
Controller08=40 VOIP
Subscriber00=TRANSPARENT ROUTER ANA[0,16,800,250,1500,80,12800,1,1,500,10500,10000,0,1000]
Subscriber01=TRANSPARENT ROUTER ANA[0,16,800,250,1500,80,12800,1,1,500,10500,10000,0,1000]
Subscriber02=TRANSPARENT ROUTER ANA[0,16,800,250,1500,80,12800,1,1,500,10500,10000,0,1000]
Subscriber03=TRANSPARENT ROUTER ANA[0,16,800,250,1500,80,12800,1,1,500,10500,10000,0,1000]
Subscriber04=TRANSPARENT ROUTER GSM[0000,00000,000000,1,1,1,SIM4,BAND(6),IMSI,TRACE(fecc)] CHINSERT ALARM ; (3)
Subscriber05=TRANSPARENT ROUTER GSM[0000,00000,000000,1,1,1,SIM4,BAND(6),IMSI,TRACE(fecc)] CHINSERT ALARM
Subscriber06=TRANSPARENT ROUTER GSM[0000,00000,000000,1,1,1,SIM4,BAND(6),IMSI,TRACE(fecc)] CHINSERT ALARM
Subscriber07=TRANSPARENT ROUTER GSM[0000,00000,000000,1,1,1,SIM4,BAND(6),IMSI,TRACE(fecc)] CHINSERT ALARM
Subscriber08=TRANSPARENT ROUTER ALARM CHMAX[8]
(1)
The first part is the same than in
Example 4.2 on page 31
.
(2)
All mobile controllers have the same number (20) so that outgoing calls will be sent
to any free mobile controller.
(3)
The subscriber settings for the mobile controller are enhanced with the keyword
CHINSERT. This setting is needed to route incoming calls to a particular mobile mod-
ule. With this keyword it is possible to send incoming calls from mobile controller 04
to FXS port 10 and so on.
Содержание CellX 3G-4
Страница 1: ...CELLX Box Systems Manual Software version 17 1 ...
Страница 7: ...1 Overview ...
Страница 12: ...2 System security and hardware overview ...
Страница 19: ...3 CELLX Box installation ...
Страница 23: ...4 Configuration ...
Страница 43: ...5 Adapting the config files ...
Страница 57: ...6 Maintenance ...
Страница 63: ...6 Maintenance Page 63 CELLX box 17 1 002 11 Send the trace to customer service 1 2 3 ...