4.61 Location of cryo-surface
The surface should be clear of any moving parts within the vacuum system.
No closer than 25mm to any chamber wall
Out of direct line of sight with heaters or other forms of heat (magnetrons etc) – if this is
unavoidable then the surface can be effectively shielded by aluminium foil.
In systems where there is a great deal of water evolved such as roll / web coating of paper
and other materials or where the film is moisture sensitive process improvements can be made
by placing the cryo-surface close to the point of moisture generation e.g. The unwind area of a
web coater.
Consideration should be given to where the trapped water goes once the surface has been
defrosted a drain may be required if there is a lot of water.
Do not place refrigerant couplings within the vacuum system.