Telegesis
TG-EAPE-PM-006-102 7
EAP-E
Product Manual
1.02
Figure 4: EAP-E setup using Telnet to port 9999
For example if you want to change the settings of the serial port speed press ‘1’ followed by
<enter>. Following on you are asked to specify the baudrate (19200), I/F Mode (4C), Flow (00),
port number (10001), and other parameters. To enter a value for a parameter, type the value and
press <enter>, or to confirm a current value, just press enter. When you are finished, save the new
configuration (option 9). The unit reboots.
Please note: When changing the default serial port settings (baudrate, flow control, parity,
data bits), identical settings must be used for the Lantronix® XPort® Direct
TM
and the
ETRX2, otherwise communication will not be possible.
For a detailed description of the menu settings please consult the XPort® Direct
TM
user guide
available from
www.lantronix.com
.
The DeviceInstaller is used to change the configuration of the EAP-E on the Ethernet side. In most
cases there is no need to alter any of the Ethernet settings and so the DeviceInstaller can usually
be ignored.
4.1 Creating Virtual COM Ports
If accessing the serial port of the remote ETRX2 using Telnet is inconvenient for your application,
potentially because you want your application to work with either the Telegesis ETRX2USB,
©2008 Telegesis (UK) Ltd
EAP-E Product Manual (Rev 1.02)