background image

Telegesis  

TG-EAPE-PM-006-102 5 

 

EAP-E 

 

Product Manual 

1.02 

 

 

 

4  Device Installation and Operation 

 
In order to install the device connect the EAP-E to a suitable power supply with the positive supply 
in the centre of the plug. After that connect it to your network hub. 
 

 

Figure 1: EAP-E Installation 

 
If a DHCP server is connected to your network the EAP-E will automatically acquire an IP address. 
In most cases the IP address obtained by the EAP-E can be found out by accessing the DHCP 
server, but there is also an easier way to do that. 
 
The Lantronix® DeviceInstaller tool downloadable from 

www.lantronix.com

  or included on a CD-

ROM with your EAP-E can be used to identify EAP-E devices on the local network either with or 
without DHCP. 
 
To do this simply follow these steps: 
 

1.  Install and execute the Lantronix® DeviceInstaller 
2.  If your PC has more than a single network adapter a message will prompt at start-up 

requiring you to specify which adapter connects to the local network to which the EAP-E is 
connected. 

3.  Click the Search button to find the EAP-E device on your network 
4.  If required a fixed IP address can now be assigned by pressing the “Assign IP” button and 

following the displayed wizard. 

5.  To test the communication with the EAP-E select the unit from the main window list and 

click 

Tools->Ping

 
Once the IP address of the EAP-E is known it is possible to open a telnet session connecting to 
the built-in ETRX2. By default the port connecting to the ETRX2 is port number 10001 as shown in  
Figure 3. Please note that Figure 3 also shows a local command echo, which is why the characters 
of the command ATI are doubled.  
 

©2008 Telegesis (UK) Ltd 

 

EAP-E Product Manual (Rev 1.02) 

Содержание EAP-E

Страница 1: ...Telegesis TG EAPE PM 006 102 1 EAP E Product Manual 1 02 TG EAPE PM 006 102 EAP E and EAP E PA Ethernet Access Point PRODUCT MANUAL Telegesis 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Страница 2: ...S 4 3 OPERATING CONDITIONS 4 4 DEVICE INSTALLATION AND OPERATION 5 4 1 Creating Virtual COM Ports 7 5 FIRMWARE CHANGES AND UPGRADES 11 5 1 Device Reset and manually Entering the Bootloader 11 6 SCHEMA...

Страница 3: ...e to connect to one or more local EAP Es via the internet allowing remote interaction with local ZigBee networks Using the Ember bootloader custom firmware and firmware upgrades can be downloaded via...

Страница 4: ...Conditions Typical values at 25 C Parameter Min Typ Max Units Condition Supply Voltage Vdd 4 5 5 6 V 235 275 mA TX 3dBm Supply Current EAP E 235 275 mA RX 300 400 mA TX 17dBm Supply Current EAP E PA 2...

Страница 5: ...his simply follow these steps 1 Install and execute the Lantronix DeviceInstaller 2 If your PC has more than a single network adapter a message will prompt at start up requiring you to specify which a...

Страница 6: ...respective port of the corresponding local EAP Es All you need now to connect to your ZigBee network via the internet is the remote IP address and the port number Figure 3 A Telnet Session to the EAP...

Страница 7: ...drate flow control parity data bits identical settings must be used for the Lantronix XPort DirectTM and the ETRX2 otherwise communication will not be possible For a detailed description of the menu s...

Страница 8: ...ese simple steps 1 Download and Install the Lantronix CPR 2 Make sure your EAP E is installed and correctly configured 3 Execute the CPR Manager 4 Select Device Search All EAP Es in the local network...

Страница 9: ...duct Manual 1 02 Figure 5 The Lantronix CPR After this process any application can access the embedded ETRX2 as though it was connected to the local machine s COM port as shown in Figure 6 2008 Telege...

Страница 10: ...Telegesis TG EAPE PM 006 102 10 EAP E Product Manual 1 02 Figure 6 Telegesis Terminal accessing a EAP E using CPR 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Страница 11: ...esis Terminal Use DeviceInstaller to change Lantronix module back to 19200 baud Connect Telegesis Terminal Resume normal operation with new firmware Alternatively access to the SIF programming interfa...

Страница 12: ...h are not fitted The serial port including the handshaking lines as well as the reset and A D2 lines can be accessed via labelled pads X2 is the SIF connector which allows programming and custom firmw...

Страница 13: ...Telegesis TG EAPE PM 006 102 13 EAP E Product Manual 1 02 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Страница 14: ...rier Boards fitted with ETRX2 modules 1 x ETRX2 PA MCB with ETRX2 PA Module 1 x AA Battery Holders with leads 1 x USB cable 1 x ETRX2USB USB stick 1 x ETRX2HRHW PA Module with Hirose connector for ext...

Страница 15: ...r improvements without prior notification All information is correct at time of issue Telegesis UK Ltd does not convey any license under its patent rights or assume any responsibility for the use of t...

Отзывы: