Figure 2: The Lantronix DeviceInstaller
The default Port number of 10001 can be changed to any port number in order to allow multiple
EAP-Es to be addressed via the internet. To do this the local router/firewall needs to be set up to
forward incoming ports to the respective port of the corresponding local EAP-Es. All you need now
to connect to your ZigBee® network via the internet is the remote IP address and the port number.
Figure 3: A Telnet Session to the EAP-E
In order to change the configuration data, such as the port number simply open a telnet connection
to port number 9999, which is the configuration port and follow the setup menu. Alternatively you
can use the Lantronix® DeviceInstaller to do this as shown in Figure 4.
©2008 Telegesis (UK) Ltd
EAP-E Product Manual (Rev 1.02)