1.02 

 

 

7 Ordering 

Information 

Table 3.  Ordering Information 

Ordering/Product Code 

Description 

EAP-E  

 

 

Access Point based on standard ETRX2 

 

  AT Style Command Interpreter  

  Integrated 2.4GHz Antenna  

 

EAP-E-PA  

 

 

Access Point based on ETRX2-PA 

 

  AT Style Command Interpreter 

  Integrated 2.4GHz Antenna 

 

ETRX2DVKA  

 

 

Development Kit with: 

 

  1 x ETRX2HW Module with Board to Board Connector 

  1 x ETRX2DV Development Board 

  2 x ETRX2 Modules soldered to 

  2 x ETRX2MCB Module Carrier Boards  

  2 x AA Battery Holders with Leads & Connector Plugs 

  1 x USB Cable  

 

ETRX2DVKA-Plus    

 

 

Telegesis Development Kit with: 

 

  1 x ETRX2DV Development Board 

  1 x ETRX2HW Module with a fitted Harwin 

  1 x ETRX2MCB Carrier Boards fitted with ETRX2 modules 

  1 x ETRX2-PA MCB with ETRX2-PA Module 

  1 x AA Battery Holders with leads 

  1 x USB cable 

  1 x ETRX2USB USB stick 

  1 x ETRX2HRHW-PA Module with Hirose connector for 

external antenna and Harwin 

  1 x ½ Wave antenna 

  1 x 100mm cable to connect module to antenna 

 

ETRX2  
 

Telegesis Wireless Mesh Networking Module with Ember 
ZigBee® Technology: 

 

  Telegesis AT Style Command Interpreter and  

 Ember’s 

EmberZNet2.x 

stack 

  Integrated 2.4GHz Antenna  

 

Notes: 

 

  Customers’ PO’s must state the Ordering/Product Code. 

  There is no “blank” version of the ETRX2 Module available. All Modules carry both the 

EmberNet Stack and the Telegesis AT style Command Layer.  Where customers wish to 
program custom firmware they can simply overwrite the existing firmware 

  Please contact Telegesis if you require additional AT style commands or specific integration 

assistance. 

 

©2008 Telegesis (UK) Ltd 

 

EAP-E Product Manual (Rev 1.02) 

Содержание EAP-E

Страница 1: ...Telegesis TG EAPE PM 006 102 1 EAP E Product Manual 1 02 TG EAPE PM 006 102 EAP E and EAP E PA Ethernet Access Point PRODUCT MANUAL Telegesis 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Страница 2: ...S 4 3 OPERATING CONDITIONS 4 4 DEVICE INSTALLATION AND OPERATION 5 4 1 Creating Virtual COM Ports 7 5 FIRMWARE CHANGES AND UPGRADES 11 5 1 Device Reset and manually Entering the Bootloader 11 6 SCHEMA...

Страница 3: ...e to connect to one or more local EAP Es via the internet allowing remote interaction with local ZigBee networks Using the Ember bootloader custom firmware and firmware upgrades can be downloaded via...

Страница 4: ...Conditions Typical values at 25 C Parameter Min Typ Max Units Condition Supply Voltage Vdd 4 5 5 6 V 235 275 mA TX 3dBm Supply Current EAP E 235 275 mA RX 300 400 mA TX 17dBm Supply Current EAP E PA 2...

Страница 5: ...his simply follow these steps 1 Install and execute the Lantronix DeviceInstaller 2 If your PC has more than a single network adapter a message will prompt at start up requiring you to specify which a...

Страница 6: ...respective port of the corresponding local EAP Es All you need now to connect to your ZigBee network via the internet is the remote IP address and the port number Figure 3 A Telnet Session to the EAP...

Страница 7: ...drate flow control parity data bits identical settings must be used for the Lantronix XPort DirectTM and the ETRX2 otherwise communication will not be possible For a detailed description of the menu s...

Страница 8: ...ese simple steps 1 Download and Install the Lantronix CPR 2 Make sure your EAP E is installed and correctly configured 3 Execute the CPR Manager 4 Select Device Search All EAP Es in the local network...

Страница 9: ...duct Manual 1 02 Figure 5 The Lantronix CPR After this process any application can access the embedded ETRX2 as though it was connected to the local machine s COM port as shown in Figure 6 2008 Telege...

Страница 10: ...Telegesis TG EAPE PM 006 102 10 EAP E Product Manual 1 02 Figure 6 Telegesis Terminal accessing a EAP E using CPR 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Страница 11: ...esis Terminal Use DeviceInstaller to change Lantronix module back to 19200 baud Connect Telegesis Terminal Resume normal operation with new firmware Alternatively access to the SIF programming interfa...

Страница 12: ...h are not fitted The serial port including the handshaking lines as well as the reset and A D2 lines can be accessed via labelled pads X2 is the SIF connector which allows programming and custom firmw...

Страница 13: ...Telegesis TG EAPE PM 006 102 13 EAP E Product Manual 1 02 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Страница 14: ...rier Boards fitted with ETRX2 modules 1 x ETRX2 PA MCB with ETRX2 PA Module 1 x AA Battery Holders with leads 1 x USB cable 1 x ETRX2USB USB stick 1 x ETRX2HRHW PA Module with Hirose connector for ext...

Страница 15: ...r improvements without prior notification All information is correct at time of issue Telegesis UK Ltd does not convey any license under its patent rights or assume any responsibility for the use of t...

Отзывы: