background image

Foreword 

-

 Water and Wastewater Products

This instruction manual is designed to help you gain a thorough understanding of the operation of

 

the equipment. Teledyne ISCO recommends that you read this manual completely before placing

 

the equipment in service.
Although Teledyne ISCO designs reliability into all equipment, there is always the possibility of a

 

malfunction. This manual may help in diagnosing and repairing the malfunction.
If  a  problem  persists,  call  or  e-mail  Teledyne  ISCO  technical  support  for  assistance.  Simple

 

difficulties  can  often  be  diagnosed  over  the  phone.  For  faster  service,  please  have  your  serial

 

number ready.
If it  is necessary  to  return  the equipment  to  the factory  for  service,  please  follow  the shipping

 

instructions  provided  by  technical  support,  including  the  use  of  the  Return  Merchandise

 

Authorization (RMA) specified. Be sure to include a note describing the malfunction. This will aid

 

in the prompt repair and return of the equipment.

 

No item may be returned for service without a 

Return Material Authorization (RMA) number issued by Teledyne.

Teledyne ISCO welcomes suggestions that would improve the information presented in this manual

 

or enhance the operation of the equipment itself.

Teledyne ISCO is continually improving its products and reserves the right to change product

 

specifications, replacement parts, schematics, and instructions without notice.

Contact Information

Customer Service

Phone:

(800) 228-4373

(USA, Canada, Mexico)

(402) 464-0231

(Outside North America)

Fax:

(402) 465-3022

Email:

[email protected]

Technical Support

Phone: 

 Toll Free (866) 298-6174 (Samplers and flowmeters)

Email:

[email protected]

Return 

equipment to:   4700 Superior Street, Lincoln, NE 68504-1398

Other Correspondence

Mail to: 

 P.O. Box 82531, Lincoln, NE 68501-2531

Warranty and Operation Manuals can be found on our website at:

www.teledyneisco.com

Содержание TIENet 350

Страница 1: ...y 69 4353 024 Copyright 2021 All rights reserved Teledyne ISCO Revision E August 2021 Use and Disclosure of Data Information contained herein is classified as EAR99 under the U S Export Administration...

Страница 2: ......

Страница 3: ...RMA specified Be sure to include a note describing the malfunction This will aid in the prompt repair and return of the equipment No item may be returned for service without a Return Material Authori...

Страница 4: ......

Страница 5: ...d une mani re autre que celles qui sont specifi es dans ce manuel la protection fournie de l instrument peut tre affaiblie cela augmentera votre risque de blessure Hazard Severity Levels This manual...

Страница 6: ...mboles de s curit Ce symbole signale l existence d instructions importantes relatives au produit dans ce manuel Ce symbole signale la pr sence d un danger d lectocution Warnungen und Vorsichtshinweise...

Страница 7: ...able 2 5 2 5 Installing the 350 AV Sensor 2 9 2 5 1 Installation Considerations 2 9 2 5 2 Mounting Rings 2 10 2 5 3 Spring Rings 2 10 2 5 4 Scissors Mounting Ring 2 12 2 5 5 Completing the Sensor Inst...

Страница 8: ...trips 2 6 2 6 Installing cable with a cord grip fitting 2 6 2 7 TIENet Device terminal connections 2 7 2 8 Attach wired terminal strip to case board socket 2 7 2 9 Insert the cable reference tubing in...

Страница 9: ...sor is mounted in the flow stream normally at the bottom of the channel It measures average velocity using con tinuous ultrasonic sound waves to produce a Doppler effect in which the frequency of a wa...

Страница 10: ...reflected wave indicates forward or reverse flow The degree of change is proportional to the velocity of the flow stream 1 1 2 350 Level Operation The 350 sensor s internal differential pressure tran...

Страница 11: ...with integral digital temperature compensation coefficients Rangeb 0 010 to 3 05 m 0 033 to 10 ft Pressure Rating 5 PSI Maximum Submersible Depth 10 55 m 34 6 ft Accuracyc 0 10 FS Typical Long Term S...

Страница 12: ...AV Sensor w 23m Cable 60 4354 114 TIENet 350 AV Sensor w 2ft Cable TIENet Plug Connector 60 4354 117 Cord grip fitting 3 4 NPT for TIENet cable 209 0073 12 Bulk TIENet Cable Cut to Length 60 4304 050...

Страница 13: ...vices In accordance with the FreeRTOS license FreeRTOS source code is available on request For more information visit www FreeRTOS org 1 5 Unpacking Instructions When the system arrives inspect the ou...

Страница 14: ...preventive measures are fully understood 2 1 1 Site Conditions Components are often installed in confined spaces Some examples of confined spaces include manholes pipelines digesters and storage tank...

Страница 15: ...ended distance between system components is 305 meters 1 000 feet Longer distances may result in signal degra dation and drops in voltage Distance of 100 Feet or Less The un vented TIENet expansion bo...

Страница 16: ...supply for the bubbler Signature bubbler systems will already have a desiccator installed If you are adding a 350 AV sensor to a non bubbler system you will also need to add an external desiccator Re...

Страница 17: ...his tubing configuration will operate satisfactorily with the 350 AV sensor in most situations you can configure the tubing to utilize both chambers of the external desiccator to increase drying power...

Страница 18: ...r manual for instructions on accessing the instrument s interior components WARNING Before proceeding ensure that the flow meter has been disconnected from mains power Note The steps that follow inclu...

Страница 19: ...ice cable end through the sealing nut and seal and through the cable nut Lightly tighten the sealing nut just enough to hold the cable in place while installing the connector Figure 2 6 Installing cab...

Страница 20: ...round the YELLOW and BROWN wires The BRAID DRAIN wire is the bare drain emerging from the sur rounding braided shield inside the cable jacket It is not neces sary to prevent the two braids from coming...

Страница 21: ...osure taking care not to put any stress on the con nections 7 Tighten the cord grip sealing nut Figure 2 10 Figure 2 10Position and secure the cable 8 Close the front panel and fasten it shut with the...

Страница 22: ...th uniform flow An example of uniform flow is shown at left Avoid poor channel conditions Poor channel conditions may cause incorrect or erratic readings Areas to avoid are Outfalls or channel interse...

Страница 23: ...e installed using primary measuring devices CAUTION Use gloves and eye protection when assembling and installing the rings in a pipe Though deburred the edges of the stain less steel can cut if improp...

Страница 24: ...he stream and could possibly be damaged or lost Make sure the sensor cable is securely fastened along the back downstream edge of the ring Otherwise the sensor may provide inaccurate level readings un...

Страница 25: ...ing force of the ring by flattening the ring slightly 2 5 4 Scissors Mounting Ring For pipes larger than 15 in diameter Teledyne ISCO offers the adjustable Scissors Ring also known as the Universal Mo...

Страница 26: ...sing appropriate anchoring hardware To prevent debris from catching on the probe cable it is important to attach the cable to the mounting ring so it offers as little resistance to the flow as possibl...

Страница 27: ...tangling and trapping debris Install the cable so that it is not at risk of damage resulting from other activity taking place in the area 2 6 Street Level Installation System The Street Level Install...

Страница 28: ...When the scan is complete the 350 appears in the list of connected devices ready to be con figured with the steps shown in Figure 3 2 on the following page Note From the Hardware Setup menu Configure...

Страница 29: ...locity Sensor Section 3 Setup and Programming for the Signature 3 2 Figure 3 1 Character grid Done Cancel 350 Velocity A B C D E F G H I J K L M N b a Z Y X W V U T S R Q P O c d e f g h i j k l m n o...

Страница 30: ...Configure Measurements Smart Sensor Configuration The sensors are being configured Please wait Smart Sensor Setup TIENet The sensors have been configured XXX Parameter XXX Parameter XXX Parameter 1 X...

Страница 31: ...calculation If this is set to false both positive and negative readings are reported Figure 3 3 Configuring level and velocity measurement Configure Options 1 Velocity Input Setup 2 Flow Rate Input Se...

Страница 32: ...ttings window Figure 3 4 Prior to making any changes to the Advanced settings record the factory settings in case you need to restore them later Input velocity coefficients can be adjusted for A B and...

Страница 33: ...r to mounting the sensor in the flow stream check the dis played level reading In open air the reading should be zero If not adjust the level to zero Note If the 350 sensor is part of the optional sub...

Страница 34: ...tep by step instruc tions for updating the firmware can be found in Section 2 of the Signature user manual If your system uses a 2160 LaserFlow module the sensor firmware can also be updated using the...

Страница 35: ...ote Teledyne ISCO recommends checking the desiccant at least every 6 months and changing renewing the desiccant before the entire compartment has changed color Figure 4 1 Desiccant indicating saturati...

Страница 36: ...y Place in a vented circulating forced air conventional oven in a well ventilated room and heat at 100 175 C 212 350 F for about three hours or until the color has returned to orange or yellow 4 4 In...

Страница 37: ...accumulated solids off the exterior of the sensor Use a brush and flowing water 3 Remove debris that has accumulated in the ports 4 The outer diaphragm is behind the small metal cover on the bottom o...

Страница 38: ...t A 1 Replacement Parts Replacement parts can be purchased by contacting Teledyne ISCO sCustomerServiceDepartment Teledyne ISCO Customer Service Department P O Box 82531 Lincoln NE 68501 USA Phone 800...

Страница 39: ...TIENet Model 350 Area Velocity Sensor Appendix A Replacement Parts List A 2 REPLACEMENT PLUG SENSOR CAP KIT FOR 60 9004 469 2100 SERIES AND TIENET DEVICES...

Страница 40: ...data from the Signature Flow Meter can be downloaded onto a USB flash drive in the form of a ddp Data Dump file To download the data 1 Connect a flash drive to the USB port on the front panel of the...

Страница 41: ...laying the filename site name device type number of data types in the site file and progress of the download 5 When the two progress bars have completed click Done to close the window Figure B 2 Signa...

Страница 42: ...Code Definitions 1 Measurement Error Unable to get valid velocity reading after a specific number of retries 3 Velocity Filter Error Unable to get valid velocity spectrum to determine what frequency r...

Страница 43: ...TIENet Model 350 Area Velocity Sensor Appendix B Velocity Error Codes B 4...

Страница 44: ...e product O ST O Represent the concentration of the hazardous substance in this component s any homogeneous pieces is lower than the ST standard limitation X ST X X Represent the concentration of the...

Страница 45: ...Warranty...