SeaBat T-Series Subsea Operator's Manual
Page 81
January 31, 2019
Version 7
Message
Description
Action
RDR Data delete failed - Filename
not available
RDR - Set new file name failed
RDR - Set Data path Failed
Disk Level Threshold: X%.
A.3.5 BITE Data Warnings
Message
Description
Action
ERROR : NSD
Non Sonar Data FIFO overflow (x
packet)
An error has occurred in
reading of BITE data. The
data buffer has overflowed.
No action needed.
A.3.6 Input Signal Warnings
Message
Description
Action
Roll Compensation is not available.
Pitch Compensation is not available.
The input data for motion is
not available or the feature is
not enabled.
Check device inputs
and cabling.
A.3.7 System Stability Warnings
Message
Description
Action
WARNING: PPS Time-stamp error
The internal clock may not be
disciplined properly resulting
in incorrect time stamp of
data.
Check 1PPS
connections and GPS
output. If uncorrected
sonar data cannot be
time stamped to 1
millisecond.
WARNING: Reduce Ping Rate or
Range - DROPPING ping
The system is overloaded
processing data. A ping has
been lost because the
processing queue is full.
Restart the software.
Reboot PC.
A.3.8 Data Subscription Warnings
Message
Description
Action
Subscriber UDP sendto() failed
Subscriber send() failed
The software was unable to
send data to a connected
client.
Check network
resources and user
permissions.
Subscribers outbound MMF buffer
memory overwrite error!
Subscribers outbound MMF buffer
read error!
Subscribers outbound MMF buffer
memory overwrite error!
The link to the user interface
running on the sonar
processor has detected a
non-critical error.
Check system
resources, shutdown all
non-critical software
applications. Reboot
processor.
Содержание SeaBat T Series