20
Configuration
Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Figure 3-2
Hardware pane with motion stabilization setting
3.4.2 Time and PPS Setup
The timing
is setup from the SUI’s I/O pane’s clock tab.
It is essential to connect and define the timing and PPS signals
correctly.
The time message could be interfaced to the T20-P by two methods:
By a serial message from the POS MV
Or by Ethernet message 7 from the POS MV
3.4.2.1 Serial Time Message
When a serial message is used for timing:
1. Connect the serial cable from the POS MV COM1 to the T20-P
COM 1 timing port. Refer to section ‘Connections’ on page 3.
2. Connect the POSMV
PPS
port to the
PPS in
port of the T20-P. Refer
to section ‘Connections’ on page 3.
3. Open the SUI I/O pane and select the correct format with the correct
communication settings as received from the POS MV. For the POS
MV normally a NMEA ZDA message is used. COM1 is the time port.
See Figure 3-3.