Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Configuration
19
Step
Action
B: Open the menu ‘
Settings
’;
C: Select
‘Installation’
;
D: Select
’POS IP Address…
’.
4
Enter in the appeared dialog box the required IP address (E.g.
10.11.10.102) and subnet mask (255.255.255.0).
Click ‘Apply’ when changed.
When the new IP address has a different range as the computer
the communication with the POS MV will be lost off course.
5
Change the computer’s IP range in the new range of the POS
MV.
3.4 SUI Configuration
This section only describes how to configure from the SUI:
The roll stabilization feature;
Timing;
Sound velocity;
And other I/O devices.
The configuration of above items is necessary for correct functionality of
the sonar.
Refer to the SeaBat User Interface manual for a full description of the
SUI.
3.4.1 Roll Stabilization
The roll stabilization is a feature of the T20-P to correct the swath width
for Roll movements. Refer to the T20-P operate manual for more details.
See Figure 3-2
. The roll stabilization is setup in the SUI’s Hardware pane.
Tick the checkbox and select the correct format, communication
parameters and sign definition.
These settings should match with the message as received from the
motion output device such as the POS MV. Normally the POS MV is set
to output a TSS1 message.
An update rate of 50Hz or higher for the motion data is needed for