Q-Flex Satellite Modem Installation and Operating Handbook
3-1
Chapter 3
Safety and Compliance Information
PLEASE READ THE FOLLOWING INFORMATION BEFORE
INSTALLATION AND USE.
3.1 Safety Compliance
To ensure operator safety, this satellite modem conforms to the provisions of EMC Low
Voltage Directive 2006/95/EC and complies with the following standard:
•
EN 60950-1:2006 ‘Safety of Information Technology Equipment, Including
Electrical Business Equipment’.
Prior to installation and at all points during operation the following points must be
observed.
•
This satellite modem must be operated with its cover on at all
times in order to provide protection from potentially lethal internal
voltages. Never operate the unit with the cover removed.
•
This satellite modem must be directly connected to a protective
earth ground at all times using the chassis ground stud situated
on the rear of the unit.
•
The power system to which this satellite modem is connected
must provide separate ground, neutral and line conductors. The
power system must have a direct ground connection. Note that
the ground stud in itself does not provide a protective earth
connection until the satellite modem is coupled to a suitable
power supply cord containing a protective earth terminal.
•
This satellite modem has double pole/neutral fusing. To ensure
operator safety, fuses should always be replaced with identical
type and rating.
•
To allow rapid disconnection from the mains in an emergency, the
equipment should be installed near the mains socket outlet,
which should be easily accessible.