Q-Flex Satellite Modem Installation and Operating Handbook
5-14
termination (crossover versus straight-through) are auto-negotiated. Line speed
and duplex can also be set to fixed values. The two Ethernet ports can be bridged
together under software control.
M&C control can be via the Simple Network Management Protocol (SNMP), an
embedded web server that sends web pages to a web browser, a Telnet-style
terminal emulation application or via TCP packets that encapsulate Paradise
Universal Protocol (PUP) commands.
SNMP is disabled by default and must be enabled before it can be
used. Once enabled, the modem will always respond to SNMP
commands regardless of whether it has been placed in a mode
that restricts user control to the front panel only.
When using the M&C interface, an M&C IP address (including subnet mask and
default gateway) must be set. An IP traffic address is not required when operating in
Ethernet bridging modes. IP addresses are described in
Section 7.8.2
.
•
Station Clock
This is a 75
Ω
BNC female connector that accepts a 1MHz to 10MHz signal, either
a square wave of >1V peak-to-peak or a sine wave at a power level of 0dBm or
greater. Alternatively, the station clock signal can be input as an RS422 signal on
the Async ESC connector.
The station clock acts as a clock for either the modem receive circuit (or, if the
input is at exactly 10MHz, for both the receive and transmit circuits). It is therefore
possible to maintain clock synchronization between several modems by feeding a
common master clock signal into all of them.