Q-Flex Satellite Modem Installation and Operating Handbook
10-2
1:n CONNECTOR
1
Ground
2
Line In
3
Line Out
4
Serial In (A) (RS232/485)
5
Serial In (B) (RS232/485)
6
Fail In
7
Fail Out
8
Serial Out (A) (RS485)
9
Serial Out (B) (RS485)
Serial In/Out
This is an uncommitted and currently unused RS232 or RS485 serial port.
Line In/Out & Fail In/Out
The 1:1 redundancy cable is wired as follows:
Modem 1
Modem 2 Signal Name
Pin 1
Pin 1
Circuit ground (screen)
Pin 2
Pin 3
On-Line signal 2-1
Pin 3
Pin 2
On-Line signal 1-2
Pin 6
Pin 7
Fail signal 2-1
Pin 7
Pin 6
Fail signal 1-2
The cable must be of the shielded variety and should be kept as short as practical.
A standard 1:1 lead (part number P1391) is available from Teledyne Paradise Datacom.
The lead is 10cm long and is designed for use when two modems are mounted vertically
adjacent to each other in the rack.