![Teledyne Piranha4 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/teledyne/piranha4/piranha4_user-manual_1080551038.webp)
38
Piranha4 8K Camera Color User's Manual
03-032-20156-02
Teledyne DALSA
Verify Temperature and Voltage
To d eterm ine the voltage and tem p eratu re at the cam era, u se the
Refresh Voltage and Refresh
Temperature
featu res fou nd in the
Camera
Information
set.
The tem p eratu re retu rned is the internal tem p eratu re in d egrees Celsiu s. For p rop er op eration, this valu e
shou ld not exceed 75 °C. If the cam era exceed s the d esignated tem p eratu re it w ill stop im aging and the
LED w ill tu rn red . Once you have d iagnosed and rem ed ied the issu e u se the
reset camera
fu nction.
The voltage d isplayed is the camera‘s input voltage.
Note:
The voltage m easu rem ent featu re of the cam era p rovid es only ap p roxim ate resu lts (typ ically w ithin
10% and d ep end ent on the voltage d rop in the cable ). The m easu rem ent shou ld not be u sed to set the
ap p lied voltage to the cam era, bu t only u sed as a test to isolate gross p roblem s w ith the su p p ly voltage.
Saving and Restoring Camera Settings
The p aram eters u sed to select, load and save u ser sets are grou p ed together u nd er the Cam era
Inform ation set of featu res. There are 8 u ser sets available and one factory set.
Camera Information
Parameter
Choices
User Set Defau lt Selector
Select the cam era p aram eters to load w hen the cam era is reset or
p ow ered u p as the Factory set, or as User Set 1 to 8.
Selecting the set from the list au tom atically saves it as the d efau lt
set.
User Set Selector
Select the Factory or User set to Save or Load .
-Factory Set
-User Set 1 to 8.
User Set Load
Load the set sp ecified by User Set Selector to the cam era and m ake
it the active / cu rrent set.
User Set Save
Save the cu rrent set as selected u ser set.
Description of the Camera Settings
The cam era op erates in one of three settings:
1.
Cu rrent session.
2.
User setting.
3.
Factory setting (read -only).
4.
Defau lt setting.
The cu rrent settings can be saved (thereby becom ing the u ser setting) u sing the User Set Save p aram eter.
A p reviou sly saved u ser setting (User Set 1 to 8) or the factory settings can be restored u sing the User Set
Selector and User Set Load p aram eters.
Either the Factory or one of the User settings can be saved as the Defau lt Setting by selecting the set in the
User Set Defau lt Selector. The chosen set au tom atically saves as the d efau lt setting and is the set load ed
w hen the cam era is reset or p ow ered u p .