CONFIGURATION & SETUP
5-19
USE AND DISCLOSURE OF DATA
Information contained herein is classified as EAR99 under the U.S. Export Administration Regulations. Export, reexport or diversion contrary to U.S. law is
prohibited.
Event codes, cont.
IF Sn=Ihhibit off, with S (Sensor number) or SYS
NW XXXXXXXXX=New sensor, with last 9 digits of serial number
DW XXXXXXXXX=Diff sensor x, with last 9 digits of serial number
Ax (O/F) Sn XXXXXX=Alarm x, with (On/oFf), S (123), (gascons)
FA (O/F) Sn SSSS=Fault, with (On/oFf), S (123), (sensorstatus)
GD YYMMDD=Get Date, with year, month, day
GT HHMMSS=Get Time, with hour, minute, second
RC XXXX=RCON bits, with (RCON). Reserved for Technical Support.
OS XXXX=OSCON bits. For Internal use only.
CL =Clear log
PW x accepted/Failed= X is user access level
Sn GasConc=Only log when changed on screen
TN TXName=
TS TXSerialNumber=
TV TXCodeVersion=
RF =Restore factory default
Rn No Latch:Fsafe=
FC nXXXh NAN=Not a number float
FC nXXXh INF=Infinity float
FC nXXXh DEB=Debug mbregister
C[123] message=Span
Z[123] message=Zero
SM nXXX yyyyyyyy=Save to sensormb register, nXXX isregister"
address, yyyyyyyy isvalue otstring
TM OOOO=Saveto TX
mb register, OOOO is defined in gui_defines.hSETUP_PARMS. The function
saves ALL to TX FRAM anyway (don’t care what OOOOis)
TT xxxCH [01]=TXtemperature, heater o or 1 (on/off)
Table 5-7: Datalog Menu Parameters
Item
Sub-Item
Description*