TXSerialNumber
sn: example 115Ayywwnnnnnn
115 is the company(Monroe)
A is assembly (s is subassy)
08 is the year of manufacture
16 is the week of manufacture
xxxxxx is the sequential number produced within the
week. 14 chars ASCII
CHAR 16
Tx Info
40775 306
R
TXCodeVersion
Firmware version
4 chars, ASCII
CHAR 6
Tx Info
40778 309 R/W
TXLatitude
10 chars. Null terminated
CHAR 12
Tx
Setup
40784 30F R/W
TXLongitude
10 chars. Null terminated
CHAR 12
Tx
Setup
Table 5-15: MODBUS Registers - Transmitter Configuration Parameters (Continued)