Linea GigE Series Camera
Operational Reference
•
63
Using Flat Field Correction
When using CamExpert, from the menu bar enable Flat Field correction
(Pre-Processing • Flat Field Correction • Hardware). Now when doing a live grab or snap, the
incoming image is corrected by the current flat field calibration data for each pixel.
Use the CamExpert menu function Tools • Flat Field Correction • Load to program the camera with
the flat field correction image from previously saved calibration data. CamExpert allows saving and
loading calibration data for all cameras used with the imaging system.
GigE Vision application implement features as described in the section Advanced Processing
controls.
Cycling Preset Mode Control Category
The Linea GigE Cycling Preset controls, as shown by CamExpert, groups parameters used to
configure the camera Cycling features. Cycling controls allow the user to configure a number of
camera operational states and then have the camera automatically switch between states in real-
time. Only the features programmed to change are updated when switching between camera
states, thus ensuring immediate camera response. A setup example follows the feature table.
Parameters in gray are read only, either always or due to another parameter being disabled.
Parameters in black are user set in CamExpert or programmable via an imaging application
Features listed in the description table but tagged as Invisible are usually for Teledyne DALSA or
third party software usage—not typically needed by end user applications.
Содержание Linea GigE 2K
Страница 101: ...Linea GigE Series Camera Network Overview Tools 99...
Страница 103: ...Linea GigE Series Camera Technical Specifications 101 Linea GigE 2k and 4k Note Linea GigE 2k 4k with M42x1 Lens Mount...
Страница 106: ...104 Technical Specifications Linea GigE Series Camera...
Страница 112: ...110 Technical Specifications Linea GigE Series Camera EC FCC Declarations of Conformity...
Страница 113: ...Linea GigE Series Camera Technical Specifications 111...