104
208528 REV M
Operations Manual, 7RU SSPA Chassis
Table 7-7: System Setting Details
Data
Address
Min. Data
Length
(bytes)
Description
Limits and valid values
0 1
Device Type
(read only)
0 = Reserved;
1 = RM SSPA;
2 = CO SSPA;
3 = RCP2/FPRC; 4 = RCP2-1000-CO;
5 = RCP2-1000-RM; 6 = RCP2-1000-RCP;
7 = VSAT BUC=7 (Version 4.00*)
1
1
System Operational Mode
Designator
0 = Standalone Mode; 1 = 1:1 Redundant Mode;
2 = 1:2 Redundant Mode; 3 = 1:1 Phase Combined (v.
4.70); 4 = 1:2 Phase Combined (v. 4.98);
5 = Maintenance Switch (v. 6.00*)
2
1
System Switch Mode
0 = Auto; 1 = Manual; 2 = Switch Lock
3
1
Control Mode
0 = Local; 1 = Remote
4
1
Fan Speed
0 = Low; 1 = High; 2 = Auto
5
1
Mute
0 = Mute OFF; 1 = Mute ON
6 1
Serial Protocol
Select
0 = Normal; 1 = Terminal Mode; 2 = Locus (No longer sup-
ported, beginning with v. 4.00)
7
1
Baud Rate
0 = 9600; 1 = 2400; 2 = 4800; 3 = 19200; 4 = 38400
8
1
Network Address
Valid Values: 0 - 255
9
1
Serial Interface
0 = RS232; 1 = RS485; 2 = IPNet (v. 2.50*);
3 = SNMP (v. 4.00*)
10
1
Auxiliary Fault Handling
0 = Disable Fault Checking; 1 = Major Fault;
2 = Minor Fault; 3 = Major Fault + SSPA Mute
11
1
Auxiliary Fault Logic
0 = Fault on Logic High; 1 = Fault on Logic Low
12 1
RF Switch Fault
Handling
0 = Disable Fault Checking; 1 = Major Fault;
2 = Minor Fault; 3 = Mute on Switch
13
1
Fault Latch
0 = Disable; 1 = Enable
14 1
BUC Fault
Handling
0 = Disable Fault Checking; 1 = Major Fault;
2 = Minor Fault; 3 = Major Fault + SSPA Mute
15
1
BUC Fault Logic
0 = Fault on Logic High; 1 = Fault on Logic Low
16
1
User Password
Valid Values: 0 - 255
17
1
Standby Select
0 = Standby; 1 = Online
18
1
Buzzer
0 = Disable; 1 = Enable
19
1
Menu Password Protection 0 = Disable; 1 = Enable
20
1
RF Units
0 = dBm; 1 = Watts (v. 3.40*)
* Version numbers listed indicate the version in which the listed feature was introduced.
(Continued)
22
1
HPA Status
0 = HPA1; 1 = HPA2; 2 = HPA3 (v. 3.10*; 1:2 mode only)
21
1
Standby Mode
0 = Hot Standby; 1 = Cold Standby
23
1
Priority Select (1:2 mode) 0 = Pol1; 1 = Pol2 (v. 3.10*)
24
1
Fwd. RF Flt Handling
0 = Disable; 1 = Low RF Major Fault; 2 = Low RF Minor
Fault; 3 = ALC; 4 = High RF Major Fault (v. 6.14);
5 = High RF Minor Fault (v. 6.14); 6 = High RF Fault +
Mute (v. 6.14)
25
1
Hi Refl. RF Flt Handling 0 = Disable; 1 = Major Fault; 2 = Minor Fault
26
1
SSPA Attenuation
Valid values: 0 - 200; 0.1 dBm per 1 value
27
1
Low Fwd RF Threshold Valid values: 0 - 80; 1 dBm per 1 value
28
1
High Refl. RF Threshold Valid values: 0 - 80; 1 dBm per 1 value
Содержание 7 RU Chassis
Страница 10: ...10 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 30: ...30 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 78: ...78 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 84: ...84 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 94: ...94 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 113: ...Operations Manual 7RU SSPA Chassis 208528 REV M 113 Figure 7 8 Terminal Mode Session Example...
Страница 138: ...138 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 144: ...144 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...