CrossSync PHY
Depending on the configuration, the Teledyne LeCroy PCI Express Gen4 x4 M.2 M-Key Interposer includes CrossSync
PHY capability, enabling:
•
Easy signal access to sideband signals, power rail and refclk probing points
•
Pre-installed connections on data lanes for Teledyne LeCroy DH Series high-bandwidth differential oscilloscope
probes (optional)
•
Time-synchronization and integrated cross-analysis between PETracer protocol analysis software and MAUI
oscilloscope software (optional)
Signal Name
PE210UIA-X
PE210UIA-X-1PHY PE210UIA-X-2PHY PE210UIA-X-4PHY
Pin Headers
CLK_32KHZ SUSCLK
X
X
X
X
DAS/DSS LED_1#
X
X
X
X
ALERT#IN
X
X
X
X
PEDET
X
X
X
X
PWRDIS
X
X
X
X
PLN#
X
X
X
X
PLA_S3#
X
X
X
X
VIO_CFG
X
X
X
X
PERST#IN
X
X
X
X
SMB_CLK
X
X
X
X
DEVSLP
X
X
X
X
WAKE#
X
X
X
X
CLKREQ#IN
X
X
X
X
SMB_DATA
X
X
X
X
MMCX Connectors
Refclk
X
X
X
X
3.3V rail voltage
X
X
X
X
3.3V rail current
X
X
X
X
DH Series Differential Probe Connections (Optional)
L0 Upstream
X
X
X
L0 Downstream
X
X
X
L1 Upstream
X
X
L1 Downstream
X
X
L2 Upstream
X
L2 Downstream
X
L3 Upstream
X
L3 Downstream
X
8