VS1 Installation, Configuration & Operating Guide
21
Configuring the PEU 205 and 200
Each PEU 205 and PEU 200 has 16 ports. Ports 1–8 can be configured as either CO lines or stations.
Ports 9–16 are for stations only. Ports are addressed sequentially by the TVS. When configuring
more than one PEU, verify that each port is correctly identified before changing switch settings. It is
recommended that the PEU 205 serve as the first PEU on the system.
PEU 205 Ports
1-16 and
PEU 200 Ports
17-32 (front view)
To configure the PEU 205 or PEU 200:
1.
Attach the correct PEU labels between the RJ-11 jacks on the front of each PEU. Label the first
PEU with ports 1-16 and the second PEU with ports 17–32, and so on. It is recommended that
the PEU 205 serve as the first PEU on the system.
2.
Remove the top panel on the PEU.
WARNING!
Do not remove the smaller (top) panel, which covers the power supply. The power
supply area contains hazardous voltages and has no adjustable settings.
3.
Locate the station/CO jumper sets for Port 1. There are eight blocks of pins. Each contains
black blocks for analog, blue blocks for digital, and red blocks for remote power.
•
Ports 1–8 have both station and CO jumper sets.
•
Ports 1–4 are preset as CO ports and Ports 5–8 are set as station ports. Up to four
additional CO ports can be configured by repositioning the jumpers on Ports 5–8.
•
Ports 9–16 do not have jumpers.
Содержание VS1
Страница 16: ...Hardware ...
Страница 62: ...Tel Site ...
Страница 93: ...VS1 Editor ...
Страница 180: ...Station Options ...
Страница 208: ...Reference ...
Страница 219: ...VS1 Installation Configuration Operating Guide 211 Outbound CO Call ...
Страница 254: ...246 Reference Reload Changes dialog box ...
Страница 274: ...Index ...