20
Radio card (MASTER)
WARNING: in case that the safety devices (except for TB input) are defective or they have been
activated, it is possible to operate the door anyway, keeping pressed the command button for more
than 5 seconds. The control unit will automatically switch to hold-to-run mode.
L1
led
Flashing
: normal functioning.
ON
: transmission error or drained batteries.
L2
led
ON
: activated safety alarm, transmission error or
drained
batteries.
OFF
: normal functioning.
L3
led
Not used.
Other possible issues
Problem
Solution
None of the previous signals, but
the door doesn’t move downward
Command an opening manoeuvre until the top limit has reached.
In the closure, the door hits the
floor and opens again
- The bottom limit could be too low, adjust it upwards
- In case of uneven floor use the procedure 3.2 to deactivate the safety
edge in the last part of the closure. It is necessary to command the
closure starting from the upper limit switch in order to be effective.
The door can be operated but the
safety systems don’t activate
Check the motor direction. If wrong, swap brown and black motor wires
over (terminals 5 & 7)
The control units responds to the
commands sent by transmitters,
but the front cover is not
functioning
- Check if the connection flat cable is correctly inserted in the board plug
- If the
led is flashing once per second, the “holiday mode” is
activated (see page 15)
The fuse blows while operating
the door
Check again the wirings
L3 led
L2 led
L1 led
Led
ON
: safety alarm activate (see the specific alarm).
OFF
: normal functioning.
1 flash - pause
: keypad locked (holiday mode).
Flashing slowly
: low batteries in the bottom slat transmitter (TCSP)
Led
ON
: The control unit is powered.
Led in the front cover
telecoautomation.com
Branches:
Teleco Automation France
- France
Teleco Automation GmbH
- Germany
Teleco Automation Oceania Pty Ltd
- Australia
Headquarters:
Teleco Automation Srl
- Italy