background image

20

Radio card (MASTER)

WARNING: in case that the safety devices (except for TB input) are defective or they have been 
activated, it is possible to operate the door anyway, keeping pressed the command button for more 
than 5 seconds. The control unit will automatically switch to hold-to-run mode.

L1

 led  

Flashing

: normal functioning.

  

ON

: transmission error or drained batteries.

L2

 led   

ON

: activated safety alarm, transmission error or 

  drained 

batteries.

  

OFF

: normal functioning.

L3

 led   

Not used.

Other possible issues

Problem

Solution

None of the previous signals, but 
the door doesn’t move downward

Command an opening manoeuvre until the top limit has reached.

In the closure, the door hits the 
floor and opens again

- The bottom limit could be too low, adjust it upwards
- In case of uneven floor use the procedure 3.2 to deactivate the safety 
edge in the last part of the closure. It is necessary to command the 
closure starting from the upper limit switch in order to be effective. 

The door can be operated but the 
safety systems don’t activate

Check the motor direction. If wrong, swap brown and black motor wires 
over (terminals 5 & 7)

The control units responds to the 
commands sent by transmitters, 
but the front cover is not 
functioning

- Check if the connection flat cable is correctly inserted in the board plug
- If the 

 led is flashing once per second, the “holiday mode” is 

activated (see page 15)

The fuse blows while operating 
the door

Check again the wirings

L3 led

L2 led

L1 led

Led 

  

  

ON

: safety alarm activate (see the specific alarm).

  

OFF

: normal functioning.

  

1 flash - pause

: keypad locked (holiday mode).

  

Flashing slowly

: low batteries in the bottom slat transmitter (TCSP)

Led 

 

ON

: The control unit is powered.

Led in the front cover

telecoautomation.com

Branches:

Teleco Automation France 

- France

[email protected]

Teleco Automation GmbH 

- Germany

[email protected]

Teleco Automation Oceania Pty Ltd 

- Australia

[email protected]

Headquarters:

Teleco Automation Srl 

- Italy

[email protected]

Содержание TVNRG868A01

Страница 1: ...Product TVNRG868A01 Doc TEMP Date 07 09 2018 Control system for garage doors Installer s instruction manual...

Страница 2: ...emorization 4 2 Double channel memorization 4 3 Single channel Courtesy light ON OFF 4 4 Four channels memorization 4 5 Remote memorization of the first transmitter 4 6 Remote memorization of further...

Страница 3: ...n with shock sensor TVSSH868A01 and BST25S and integrated speaker CONNECTIONS FUNCTIONING Wired inputs for safety edge both resistive 8K2 and infrared Wired inputs for command push button and emergenc...

Страница 4: ...and transmitter 4 Safety edge wireless transmitter 1 4 2 3 6 8 1 4 2 3 1 NRG control unit 2 Tubular motor 240Vac 3 Hand transmitter 4 Safety edge wireless transmitter 5 Alarm wireless sensor 6 Wireles...

Страница 5: ...5 2 1 MOUNTING THE PRODUCT BOX DIMENSIONS OPENING THE COVER 85 mm 145 mm 290 mm 80 mm 95 mm 120 mm MOUNTING SIDE...

Страница 6: ...BK2 1 2 BOTTOM SLAT TRANSMITTER SLAVE Powered by led dip switches B1 B2 3 4 5 6 BK2 2 x 3 6V Lithium batteries 2 x 1 5V Type AA batteries 1 B K 2 2 3 4 5 6 B K 2 G re e n B ro w n W h it e 1 2 1 B K 2...

Страница 7: ...n 17 Infrared 8K2 safety edge input green 18 Infrared 8K2 safety edge input white 19 Push button common COM 20 Push button step by step N O 21 Emergency STOP push button N C 22 Emergency STOP push but...

Страница 8: ...2V 24V N O COM N C 0V 12V 24V 12 13 14 15 16 17 18 19 20 21 22 23 12 13 14 15 16 17 18 19 20 21 22 23 RX FTC010 TX FTC010 REFLEX COM N C 12Vdc 15Vdc 12 13 14 15 16 17 18 19 20 21 22 23 8K2 If no wired...

Страница 9: ...TER for 2 seconds L1 and L2 led will flash 2 Push the button of the bottom slat transmitter SLAVE for 2 seconds Its led will flash In case of correct memorization L1 will costantly flash Step 4 functi...

Страница 10: ...for 3s or wait time out time of 90s from the last button pression The buzzer makes one beep P2 P1 keep pressed 3 s ON 1 2 3 ON 1 2 3 ON This function is possible ONLY within 30 seconds from the power...

Страница 11: ...it is not stopped Open the door completely by means of a memorized transmitter The buzzer emits a long beep when the upper limit switch is reached Put on the floor exactely under the door a sturdy ob...

Страница 12: ...emorize Memorization of two buttons of any transmitter in one step with function OPEN STOP CLOSE STOP Press P1 twice and keep it pressed The buzzer emits a continuous sound Press any button of the pai...

Страница 13: ...s 5 s continuous sound intermittent sound continuous sound memorized new memorized OPEN CLOSE STOP LIGHT ON LIGHT OFF 4 5 Remote memorization of the first transmitter OPEN STOP CLOSE STOP Press P1 six...

Страница 14: ...itches see at side Sending any opening or closing door command will stop the alarm Warning optional speaker must be connected O N 2 1 Press P1 eight times and keep it pressed The buzzer emits a contin...

Страница 15: ...is successfully completed the buzzer emits a continuous sound continuous sound keep it pressed intermittent sound P2 button to delete 4x Press 3 times P3 button of a memorized transmitter and keep it...

Страница 16: ...ed P3 memorized P3 memorized P3 memorized keep it pressed 2 s The procedure can be executed only within 30 seconds from power on ON This procedure configures the time of activation of the courtesy lig...

Страница 17: ...tivates or deactivates the motor torque control The control unit will costantly check the level of current required by the motor during the movement in order to detect any anomaly in the normal operat...

Страница 18: ...fety devices have to be in conformity with EN12978 The installation of the control unit has to be done by fixing the box vertically with the cable glands downwards The product is in conformity with th...

Страница 19: ...plug check all the pins The radio card master must be paired with the bottom slat transmitter slave Bottom slat transmitter checks Check type polarity and charge level of the batteries Check functiona...

Страница 20: ...closure starting from the upper limit switch in order to be effective The door can be operated but the safety systems don t activate Check the motor direction If wrong swap brown and black motor wires...

Отзывы: