16
6.1 Auto close time setting
6.2 Courtesy light time setting
This procedure configures the time lapse between complete opening and the automatic closure (if enabled).
The default time is
30 seconds
. It is possible to set the time from 5 seconds to 180 seconds.
Press
P3
button of a memorized transmitter and keep it pressed for
5 seconds
. The buzzer will emit one beep.
Release and press it again
eight times
within 5 seconds
and keep it pressed for
2 seconds
. The buzzer will make
two
beeps at the end. In case of time-out, the control unit will sound four beeps and exit the procedure automatically.
Press once
P3
to start the counting of time. The buzzer will make one beep.
Press again
P3
to stop the counting after the desired lapse. The value will be memorized by the control unit.
START
STOP
within 5 sec.
8x
keep it (*)
pressed
( 5 s)
P3 button is
located inside the
transmitter
P3
memorized
P3
memorized
P3
memorized
P3
memorized
keep it
pressed
( 2 s)
(*)The procedure can be executed only
within 30 seconds from power on
.
ON
This procedure configures the time of activation of the courtesy light (internal and external, if present).
The default time is
90 seconds
. It is possible to set the time from 60 seconds to 12 hours.
Press
P3
button of a memorized transmitter and keep it pressed for
5 seconds
. The buzzer will emit one beep.
Release and press it again
five times
within 5 seconds
and keep it pressed for
2 seconds
. The buzzer will make
three
beeps at the end. In case of time-out, the control unit will sound four beeps and exit the procedure automatically.
Press once
P3
to start the counting of time. The buzzer will make one beep.
Press again
P3
to stop the counting after the desired lapse. The value will be memorized by the control unit.
START
STOP
5x
P3
memorized
P3
memorized
P3
memorized
P3
memorized
within 5 sec.
keep it (*)
pressed
( 5 s)
P3 button is
located inside the
transmitter
keep it
pressed
( 2 s)
(*)The procedure can be executed only
within 30 seconds from power on
.
ON