Subject to modifications and errors
Page 53 of 71
2019-06-26 edition
.021
ULN max 1t Time OFF
ms
39500
39500
39500
50
60000
Only active for:
Connection Modes: 2-wire, 4-wire (LN)
Undervoltage1 Line to Neutral
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max
.023
ULN min
U
THR
OFF
%Unom
90
90
90
10
100
U
THR
ON
Fixed Hysteresis (1% U
NOM
)
.025
ULN min t
Time OFF
ms
9500
9500
9500
50
60000
Only active for:
Connection Modes: 2-wire, 4-wire (LN)
Overvoltage2 Line to Line
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max
.027
ULL max 2
U
THR
OFF
%Unom
113
113
113
100
135
U
THR
ON
Fixed Hysteresis (1% U
NOM
)
Time OFF
Fixed to 150ms
Only active for:
Connection Modes: 3-wire, 4-wire (LN+LL)
Overvoltage2 Line to Neutral
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max
.035
ULN max 2
U
THR
OFF
%Unom
113
113
113
100
135
U
THR
ON
Fixed Hysteresis (1% U
NOM
)
Time OFF
Fixed to 150ms
Only active for:
Connection Modes: 3-wire, 4-wire (LN+LL)
Overfrequency1
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max
.055
f > off
f
THR
OFF
Hz
52,0
52,0
52,0
50,0
55,0
.056
f > on
f
THR
ON
Hz
50,05
50,05
50,05
50,0
55,0
Time OFF
Fixed to 150ms
Underfrequency1
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max
.059
f < off
f
THR
OFF
Hz
47,50
47,50
47,50
45,0
50,0
.060
f < on
f
THR
ON
Hz
47,50
47,50
47,50
45,0
50,0
Time OFF
Fixed to 150ms
Comment:
f < on has a fixed offset of 25 mHz added to the displayed value
Rate of Change of Frequency (RoCoF)
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max
.090
RoCoF
Enable Function
On
on / off
on / off
.091
RoCoF off
RoCoF
THR
OFF
mHz/s
2500
2500
2500
100
3000
.092
RoCoF on
RoCoF
THR
ON
mHz/s
2300
2300
2300
100
3000
Time OFF
Fixed window length 200ms
Auxiliary Contact type
Conformity Range
Possible Range
ID
Default
.099
Contact
n.c. (normally closed)
n.o. (normally opened)
n.c. (normally closed)
n.o. (normally opened)
n.c. (normally closed)
dis. (disabled)
Turn on Delay
Conformity Range
Possible Range
ID
Default
Min
Max
Min
Max