Figure 62: Diamond display plot
Set the thresholds for gamut. (See
selecting the
Diamond
display, compare the signal to the display to determine
out-of-gamut components. Note the following:
■
The intensity of a vector indicates its duration.
■
A momentary out-of-gamut condition appears as a faint trace. Long duration
violations show as a bright trace.
When evaluating out-of-gamut components, consider the following examples.
(See the following image.)
■
Example A:
R - Ok
G > 700 mV
B - Ok
■
Example B:
R - Ok
G - Ok
B > 700 mV
■
Example C:
R - Ok
G - Ok, 350 mV
B < 0 mV
Checking gamut
WFM2300 and WFM2200A Waveform Monitors User Manual
203