Performance veri
fi
cation
1080 24p functional lock and timing.
18.
Set the SDI A output format of the reference module to 1080 24p as follows:
a.
Press the
MODULE
button until you see SDI output you are using in
the menu.
b.
Press the
FORMAT
button.
c.
Press the left (
◄
) arrow button until
1080 24p
appears, and then press
the
ENTER
button.
d.
Press the
BACK
button to exit the menu.
19.
Set the reference unit
BLACK 1
to 1080 24p Tri-level Sync as follows:
a.
Press the
MODULE
button until you see GPS7.
b.
Press the down (
▼
) arrow button to view
BLACK 1
on the menu, and
then press
ENTER
.
c.
Press the down (
▼
) arrow button to view
SELECT FORMAT
.
d.
Press the left (
◄
) or right (
►
) arrow button to select 1080 24p, and then
press the
ENTER
button.
20.
Set the reference format of the SPG8000 unit under test to HD Tri-level
Sync as follows:
a.
Press the
REFERENCE
button.
b.
You should see
SOURCE
in the menu. If you do not, press the down
(
▼
) arrow button until it appears.
c.
Press the right (
►
) arrow button until
HD Tri-Level SYNC
appears,
and then press the
ENTER
button.
21.
Set the
BLACK 1
output of the SPG8000 unit under test to 1080 24p Tri-level
Sync as follows:
a.
Press the
BLACK
button until you see
BLACK 1-3 : HD TRI-LEVEL
SYNC RATE
on the menu.
b.
Press the right (
►
) arrow button to select
Integer
, and then press the
ENTER
button.
c.
Press the
BLACK
button until you see
BLACK 1
on the menu
d.
Press the left (
◄
) arrow button until
1080 24p
appears, and then press
the
ENTER
button.
22.
Select the SDI input on the waveform monitor.
SPG8000 Speci
fi
cations and Performance Veri
fi
cation