Performance veri
fi
cation
Option AG performance veri
fi
cation
The following procedure veri
fi
es the functionality of the Option AG serial digital
audio and silence outputs.
NOTE.
The procedure in this section only applies to SPG8000 instruments with
Option AG installed.
Required equipment
The following table lists the required equipment for the following procedure.
Table 31: Required equipment for Option AG performance veri
fi
cation
Item
Qty.
Minimum requirements
Recommended equipment
Digital Audio Monitor
1
Tektronix AMM768 or WFM8300 with
Option AUD or equivalent
Oscilloscope
1
Bandwidth: 200 MHz or higher
Tektronix TDS540D or TDS3054
75
Ω
BNC cable
1
Length: 42 inches
Tektronix part number 012-0074-00 or
Belden 1694 or
MarkerTek 1694-B-B-3
75
Ω
feed-through
terminator
1
Tektronix part number 011-0103-02
SPG8000 Speci
fi
cations and Performance Veri
fi
cation
59