TCPA300/400 Amplifiers and TCP300/400 Series Current Probes Instruction Manual
3- 11
Application Notes
This section describes some of the typical measurement applications of the
TCPA300 and TCPA400 Current Probe Amplifiers:
H
Automobile Charging Systems
H
Inductance Measurements
H
Continuity Test of Multiple-Conductor Cable
H
Measuring Inductor Turns Count
H
Power Measurement and Analysis Software Applications
Automobile Charging Systems
Most automotive charging systems are three-phase alternators with a diode
rectifier network. A meter averages current from all three phases, and cannot
detect a single-phase diode problem. Observing the charge current waveform can
quickly reveal if one diode is shorted or open.
The diagram in Figure 3--7 shows the equipment setup. Refer to Table 3--2 for
the test equipment setup. A TCP303 Current Probe was used for this high-cur-
rent, low-voltage application. The TCP303 is degaussed and clamped around the
positive battery lead from the alternator. The probe arrow is pointed away from
the alternator and toward the battery side of the circuit, to reflect conventional
current. The automobile is started and the lights are turned on to add a significant
load to the circuit.
Table 3- 2: Automobile charging systems test setup
Instrument
Control
Setting
TCPA300
COUPLING
DC
RANGE
50 A/V
Oscilloscope
Coupling
DC
Amps/Division
(Volts/Division if not using TEK-
PROBE interface cable)
10 A/Div
(200 mV/Div)
Zero-Current Reference
Center graticule line
Time Base
200
s/division
Содержание TCPA300 SERIES
Страница 4: ......
Страница 8: ...Table of Contents iv TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 12: ...Table of Contents viii TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 18: ...Service Safety Summary xiv TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 20: ...Preface xvi TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 21: ...Getting Started...
Страница 22: ......
Страница 37: ...Operating Basics...
Страница 38: ......
Страница 45: ...Reference...
Страница 46: ......
Страница 64: ...Application Notes 3 18 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 71: ...Specifications...
Страница 72: ......
Страница 86: ...Specifications 4 14 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 88: ......
Страница 89: ...Performance Verification...
Страница 90: ......
Страница 135: ...Adjustment Procedures...
Страница 136: ......
Страница 138: ...Adjustment Procedures Overview 6 2 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 146: ...TCP305 and TCP312 Adjustments 6 10 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 157: ...Maintenance...
Страница 158: ......
Страница 160: ...Customer Maintenance 7 2 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 181: ...Replaceable Parts...
Страница 182: ......
Страница 190: ...Amplifier Replaceable Parts 8 8 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 198: ...Current Probes Replaceable Parts 8 16 TCPA300 400 Amplifiers and TCP300 400 Series Current Probes Instruction Manual...
Страница 199: ...Glossary and Index...
Страница 200: ......