Performance Tests
1- 22
RSA3408A Technical Reference
4.
Check the amplitude:
a.
Press the
PEAK
key on the front panel to place the marker on the peak.
b.
Check that the marker readout is within --10 dBm
0.3 dB.
5.
Disconnect the hookup:
Disconnect the cable at the analyzer input.
RF.
6.
Modify the signal generator output:
a.
Hook up the test equipment:
Connect the signal generator output through a 50
Ω
N-N coaxial cable to
the power sensor input. See Figure 1--7 on page 1--20.
b.
Modify the signal generator controls:
Frequency
100 MHz
. . . . . . . . . . . . . . . .
Level
--20 dBm
. . . . . . . . . . . . . . . . . . . .
c.
Modify the power meter control:
Frequency
100 MHz
. . . . . . . . . . . . . . . .
d.
Adjust the output level of the signal generator so that the power meter
reads --20 dBm
0.05 dBm.
e.
Disconnect the cable from the power sensor input.
7.
Modify the test hookup and preset the instrument controls:
a.
Hook up the instruments:
Connect the signal generator output through a 50
Ω
N-N coaxial cable to
the RSA3408A
INPUT
. See Figure 1--8 on page 1--21.
b.
Modify the analyzer controls:
H
Press the
FREQUENCY/CHANNEL
key on the front panel.
H
With the
Center Freq
side key, set the frequency to 100 MHz using
the numeric keypad.
H
Press the
AMPLITUDE
key on the front panel.
H
Press the
RF Atten/Mixer
side key to select
RF Att
.
H
With the
RF Att
side key, set the attenuation to 0 dB.
Содержание RSA3408A
Страница 4: ......
Страница 8: ...Table of Contents iv RSA3408A Technical Reference...
Страница 12: ...Preface viii RSA3408A Technical Reference...
Страница 13: ...Performance Verification...
Страница 14: ......
Страница 61: ...Specifications...
Страница 62: ......
Страница 85: ......
Страница 86: ......