Calibration
Procedure—Type
502A
Using
the
test oscilloscope, check the ripple voltage at
the
output of each
power supply when the autotransformer
is
adjusted
for 117 volts. Swing the autotransformer output
voltage
from 105 volts to 125 volts while observing the
amount
of
ripple
on
the
test scope. The power supply ripple
should
remain
about the same amplitude from low line to
high
line
voltage. Return the line voltage to 117 volts.
TYPICAL
RIPPLE AMPLITUDES
Supply
Typical
Ripple
-6.2V
8mv
at
105 and 115V
-150V
8mv
+ 50% at 105 and 125V
+ 100V
8mv
+ 50%
at 105 and 125V
+350V
25mv +
50%
at 105 and 125V
2.
R879,
CAL
AMPL
Connect
the
dc voltmeter to the junction of R885 and
the cathode of V873B. See
Fig. 5-3. Adjust
R879, for a
reading
of +50 volts on
the dc voltmeter. Turn the
AMPLI
TUDE CALIBRATOR switch
to 5 mV and check
for a read
ing
of 22.5 to 27.5 volts on the dc voltmeter.
Fig.
5-3.
Location of the Amplitude Calibrator test point.
3.
CRT Alignment
Turn
the TRIGGERING LEVEL to RECURRENT, HORIZON
TAL
DISPLAY
switch to
NORMAL and turn up the INTENS
ITY
Control until a trace is visible (it may be necessary to
adjust
the Vertical Positioning control). Adjust FOCUS and
ASTIGMATISM
for sharpest trace (narrowest trace width).
Position
one
of the traces under a horizontal division of the
graticule near
the
vertical
center of the crt. Loosen the
clamp
at the base of the crt and push the crt against the
graticule, then
tighten the clamp.
Now with the red knob,
near
the
bottom of the
clamp, rotate the crt until the trace
runs
parallel to the horizontal
lines of the graticule.
4.
HV
Remove the
right side
H V shield and with a dc voltmeter
connected
to the center arm of
R833 (HORIZ SENS BAL).
Adjust
R833 until a reading of
+100 volts is obtained from
the
center
arm to ground.
Now
connect the voltmeter from
the H
V
TEST POINT to
ground. Adjust
the
HV Control for a reading of —2900
volts.
Replace HV shield.
To check
HV
regulation place
the
HORIZONTAL
DISPLAY
switch
to 2 EXT VOLTS/CM. Position the focused
spots
onto
the screen. Now while observing the focused
spot,
decrease the
line voltage with the autotransformer to
105
volts. The spots should not have shown any blooming
as
the
line voltage was decreased. Return the line voltage
to
117 volts and the
HORIZONTAL DISPLAY switch to the
NORMAL
position.
5.
INTENSITY
BALANCE Control
Increase
the INTENSITY Control to the point where the
traces
have a halo
forming around them. While observing
the
halo around each trace adjust the INTENSITY BALANCE
Control
until
the brightness of the halos is the same.
Turn
the INTENSITY down to the normal level and observe
the two traces. The
intensities should still
be about the same.
6.
ASTIG
UPPER, ASTIG LOWER
Adjustment
Place
the
HORIZONTAL DISPLAY switch in the 2 EXT
VOLTS/CM
position and rotate both
the UPPER
and LOWER
BEAM
FOCUS Controls fully clockwise. Position both beams
onto
the screen,
and adjust the ASTIG UPPER and ASTIG
LOWER
Controls so that both defocused spots are as nearly
circular
as possible. Adjust the UPPER BEAM
and LOWER
BEAM
FOCUS Controls
so that both spots are in sharp
focus.
Return the HORIZONTAL DISPLAY switch to NORMAL.
NOTE
If a
line
appears instead
of a spot, the high-
voltage
shields are not in
place.
CAUTION
It is
quite
easy to damage
the crt phosphor
when
the
spots are
in sharp focus. The INTENSITY
Control
should also be kept as low as possible
when
doing
the above adjustment.
7. GEOM
Connect
1 MILLISECONDS
time marker from a Type 180A
to
both A inputs. Position the two
traces so that only the
®I
5-3
Содержание 502A
Страница 4: ......
Страница 22: ...Circuit Description Type 502A Fig 3 2 Simplified Sweep Trigger Circuit t i CO ...
Страница 27: ...Circuit Description Type 502A Fig 3 4 Simplified Horizontal Amplifier 3 9 ...
Страница 30: ...Circuit Description Type 502A 3 12 NORMALLY CLOSED LOCATED ON REAR PANEL Fig 3 6 Simplified CRT Circuit ...
Страница 32: ...Circuit Description Type 5O2A Fig 3 7 Simplified Calibrator Circuit 3 14 ...
Страница 34: ...NOTES ...
Страница 56: ...NOTES ...
Страница 60: ...Parts List Type 502A LEFT SIDE 6 4 ...
Страница 64: ...Parts List Type 502A RIGHT SIDE 6 8 ...
Страница 67: ...Parts List Type 502A TOP 6 11 ...
Страница 70: ...Parts List Type 502A BOTTOM 6 14 ...
Страница 73: ...Parts List Type 502A REAR 6 17 ...
Страница 89: ...TYPE 502A OSCILLOSCOPE A ...
Страница 90: ...A BLOCK DIAGRAM MRH Z6 3 ...
Страница 91: ... TYPE 502A OSCILLOSCOPE A ...
Страница 92: ...A CIRCUIT NUMBERS 1 THRU 59 I Ixj 263 TIME BASE TR IGGER ...
Страница 93: ......
Страница 95: ...TI M I NG RESI 5TORS TIMING CAPACITORS TYPE 502A OSCILLOSCOPE ...
Страница 96: ...SWI6O HOLD OFF CAPACITORS 4 RESISTORS TIM ING CAPACITORS o A TIMING SWITCH job ...
Страница 98: ... 1 INPUT AMPLIFIER OUTPUT AMPLIFIER A CIR CUIT NUMSER 5 300 THR U 399 ZG3 joe ...
Страница 100: ...CMO 363 VERTICAL ATTENUATOR SWITCH A ...
Страница 103: ...TYPE 5O2A OSCILLOSCOPE OOM HEATER WIRING DIAGRAM ...
Страница 104: ...POWER SUPPLY CIRCUIT NUMBERSI 600 THRU 799 ...
Страница 106: ...CIR CUIT NUMBER S 800 THR U 869 CRT CIRCUIT c 9G4 ...
Страница 107: ...CA LIBp A TOp MULTIVIBP A TOR 1 IOOV o TYPE 5O2A OSCILLOSCOPE A ...
Страница 108: ...CAL OUT CF CALIBRATOR A CIRCUIT NUMBERS 8 7O THRU 899 4Z ...
Страница 110: ...TYPE 502A TENT S N 23430 PARTS LIST CORRECTION CHANGE TO V152 157 0104 01 Selected 6AL5 M913U 665 ...