Calibration
Procedure
—
Type
502A
13. Coaxial "Straight" Connector. (1)
14. Jumpers,
6
inch with banana
plugs. (3)
15.
A constant amplitude
sine-wave generator having
output
frequencies
of 1 kilocycle,
50
kilocycles, 100 kilocycles, 200
kilocycles,
400 kilocycles and
1 megacycle. The
generator
should also
have
a variable output amplitude from 500
μvolts
to 2 volts.
If a constant
amplitude generator is not available to
cover
the above ranges, any generator which has the
proper
frequencies
and output amplitudes may be used.
When
using a
generator which does
not have a constant
amplitude
feature
the test oscilloscope should
be used
to
monitor the output of the generator. By use of the
oscilloscope
the
output signal from the generator may be
kept
at
a constant amplitude.
By
the use of a DB
box or an attenuator system, the
signal
going
from the sine-wave generator to the Type 502A
may
be reduced to the proper
amplitude for the
high sensi
tivity
ranges,
while at the
same time the signal going from
the
sine-wave generator to the test oscilloscope may be
kept
at
a high
amplitude to enable monitoring for a constant am
plitude
of signal
out of the sine-wave generator.
Preliminary
NOMINAL
RESISTANCES OF
POWER
SUPPLIES
SUPPLY
APPROX.
RESISTANCE TO
GROUND
-150V
3.5
k
100
V
4
k
350V
10k
Connect
the
power cord
and the ac voltmeter to the out
put
of the autotransformer. Rotate the POWER AND SCALE
ILLUM
control clockwise to the ON position and adjust the
autotransformer
for an output of 117 volts (or 234 volts).
Allow
the
instrument to warm up for several minutes
before
proceeding
with the calibration adjustments. During cali
bration,
periodically check the input voltage to the instru
ment
and adjust the autotransformer as necessary to
main
tain
the voltage
at 117 or 234 volts except when the power
supply
regulation is being checked.
CAUTION
Do
not
reset
the —150 control unless the power
supply
voltages are actually out of tolerance or
you are
planning
to perform a complete calibra
tion
of the instrument.
Preset
the front-panel controls
of
the
Type
502A
as
follows:
POWER
AND SCALE ILLUM
PWR
OFF
INTENSITY
full
counterclockwise
INTENSITY
BALANCE
midrange
FOCUS (both beams)
midrange
TRIGGERING
LEVEL
midrange
TRIGGER
SELECTOR
+
LOWER AC
MODE
Switch
NORMAL
TIME/CM
1
mSEC
VARIABLE
CALIBRATED
HORIZONTAL
DISPLAY
2
EXT VOLTS/CM
HORIZONTAL
POSITION
midrange
AMPLITUDE
CALIBRATOR
OFF
HORIZ
DEF PLATE
TIME
BASE AMP
SELECTOR
The
following applies to both vertical amplifiers:
Input Selector
A-DC
SENSITIVITY
.2
VOLTS PER CM
VARIABLE
CALIBRATED
DC
BAL.
control
will be
set later.
VERTICAL
POSITION
midrange
Before
applying power to the instrument
the resistances
of
the power supplies should be checked. The typical resis
tances
of
the supplies may be found in the chart below.
1.
Low-Volfage Power
Supply
Connect
the dc voltmeter to the
output of the —150 volt
power supply. Power supply output
test
points are shown in
Fig.
5-2. Set the
—150 Control for a reading of —150 volts.
Check that
the outputs of the —6.2, +100 and
+350 volt
supplies are within the
spe or — 3% tolerances.
If either the
+100 or +350 volt supplies are out of tolerance,
reset
the
—150 control slightly until all power
supply
voltages
are
within tolerances.
Vary
the output of the autotransformer between 105 and
125
volts
(or between 210 and 250 volts) to check the regula
tion
of
the low voltage power supplies. The power supplies
must
regulate within
+ or — 3% of their correct voltages.
Fig.
5-2. Power Supply voltage test points.
5-2
®2
Содержание 502A
Страница 4: ......
Страница 22: ...Circuit Description Type 502A Fig 3 2 Simplified Sweep Trigger Circuit t i CO ...
Страница 27: ...Circuit Description Type 502A Fig 3 4 Simplified Horizontal Amplifier 3 9 ...
Страница 30: ...Circuit Description Type 502A 3 12 NORMALLY CLOSED LOCATED ON REAR PANEL Fig 3 6 Simplified CRT Circuit ...
Страница 32: ...Circuit Description Type 5O2A Fig 3 7 Simplified Calibrator Circuit 3 14 ...
Страница 34: ...NOTES ...
Страница 56: ...NOTES ...
Страница 60: ...Parts List Type 502A LEFT SIDE 6 4 ...
Страница 64: ...Parts List Type 502A RIGHT SIDE 6 8 ...
Страница 67: ...Parts List Type 502A TOP 6 11 ...
Страница 70: ...Parts List Type 502A BOTTOM 6 14 ...
Страница 73: ...Parts List Type 502A REAR 6 17 ...
Страница 89: ...TYPE 502A OSCILLOSCOPE A ...
Страница 90: ...A BLOCK DIAGRAM MRH Z6 3 ...
Страница 91: ... TYPE 502A OSCILLOSCOPE A ...
Страница 92: ...A CIRCUIT NUMBERS 1 THRU 59 I Ixj 263 TIME BASE TR IGGER ...
Страница 93: ......
Страница 95: ...TI M I NG RESI 5TORS TIMING CAPACITORS TYPE 502A OSCILLOSCOPE ...
Страница 96: ...SWI6O HOLD OFF CAPACITORS 4 RESISTORS TIM ING CAPACITORS o A TIMING SWITCH job ...
Страница 98: ... 1 INPUT AMPLIFIER OUTPUT AMPLIFIER A CIR CUIT NUMSER 5 300 THR U 399 ZG3 joe ...
Страница 100: ...CMO 363 VERTICAL ATTENUATOR SWITCH A ...
Страница 103: ...TYPE 5O2A OSCILLOSCOPE OOM HEATER WIRING DIAGRAM ...
Страница 104: ...POWER SUPPLY CIRCUIT NUMBERSI 600 THRU 799 ...
Страница 106: ...CIR CUIT NUMBER S 800 THR U 869 CRT CIRCUIT c 9G4 ...
Страница 107: ...CA LIBp A TOp MULTIVIBP A TOR 1 IOOV o TYPE 5O2A OSCILLOSCOPE A ...
Страница 108: ...CAL OUT CF CALIBRATOR A CIRCUIT NUMBERS 8 7O THRU 899 4Z ...