1.2
Specifications
The Industrial Tracker specifications are listed in Table 1-2.
Table 1-2: Industrial Tracker Specifications
Parameter
Specification
Use Environment
Industrial
Indoor/outdoor commercial/residential
Environmental Rating
IP67
Enclosure
Custom design by TEKTELIC
Humidity Vent
Mobi 3-FJ-S1-00-055
UV rated as part of other safety filings
Operating Temperature
-
40°C‒85°C
Storage Temperature for Optimal Battery
Life
-
40°C‒75°C
Operating Relative Humidity
0%‒100%, condensing
Storage Relative Humidity
0%‒100%, condensing
Size
195 mm x 101 mm x 50 mm
Weight
300 g without battery; add 95 g per battery.
Power Source
Battery powered: 1x or 2x D-cell LTC
(or 3.0 V‒3.7 V DC)
with reverse polarity protection
Network technology/Frequency band
LoRaWAN in two variants (see Table 1-1):
US915, EU868
Air Interface
LoRa
Maximum Tx Power
22 dBm
Sensing Functions
GNSS, Accelerometer, BLE, Temperature, Battery Fuel
Gauge
GNSS Features
Support of GPS/QZSS, GLONASS, Galileo, BeiDou
Support of 3 concurrent GNSSs
Data logging up to 15,000 entries
Geofencing up to 4 circular geofences
2.5 m position accuracy
TTFF:
•
26 sec cold start
•
1 sec hot start