Revision History 

Revision 

Issue Date 

Editor 

Comments 

0.1 

May 31, 2019 

Emma Tholl 

 

Initial draft. 

0.2 

Sep 23, 2019 

Reza Nikjah 

 

Added the resetting, awakening, powering off, and 
putting into DEEP SLEEP procedures. It is assumed now 
that the modules are shipped in closed IP67 enclosures 
with already installed and engaged batteries. 

 

Added Acronyms and Glossary section 

 

Completed the specification table 

 

Edited the compliance statements 

 

Made some general, minor edits 

0.3 

Oct 15, 2019 

Conor Karperien 

 

Updated design 

1.0 

Nov 5, 2019 

Reza Nikjah 

 

Released 

1.1 

Nov 13, 2019 

Reza Nikjah 

 

Removed Industrial Tracker variant models not yet 
available 

Содержание T0006129

Страница 1: ...ird parties 2019 TEKTELIC Communications Inc all rights reserved All products names and services are trademarks and registered trademarks of their respective companies TEKTELIC Communications Inc 7657...

Страница 2: ...wering off and putting into DEEP SLEEP procedures It is assumed now that the modules are shipped in closed IP67 enclosures with already installed and engaged batteries Added Acronyms and Glossary sect...

Страница 3: ...Overview 7 1 2 Specifications 8 2 Installation 10 2 1 Included Product and Installation Material 10 2 2 Safety Precautions 10 2 3 Unpacking and Inspection 10 2 4 Commissioning and Awakening 10 2 5 Mo...

Страница 4: ...T Industrial Tracker User Guide T0006279_UG Version 1 1 TEKTELIC Communications Inc Confidential Page 4 of 17 List of Tables Table 1 1 Industrial Tracker Model 7 Table 1 2 Industrial Tracker Specifica...

Страница 5: ...UG Version 1 1 TEKTELIC Communications Inc Confidential Page 5 of 17 List of Figures Figure 1 1 The Industrial Tracker module 8 Figure 2 1 The Industrial Tracker magnetic wake up pattern 11 Figure 2 2...

Страница 6: ...Ra IoT Industrial Tracker IoT Internet of things IP ingress protection LED light emitting diode LoRa a patented long range IoT technology acquired by Semtech LoRaWAN LoRa wide area network a network p...

Страница 7: ...compatibility a LoRa based radio a GNSS device an accelerometer and three battery gauges Table 1 1 presents the available Industrial Tracker model Table 1 1 Industrial Tracker Model The main features...

Страница 8: ...rature 40 C 85 C Storage Temperature for Optimal Battery Life 40 C 75 C Operating Relative Humidity 0 100 condensing Storage Relative Humidity 0 100 condensing Size 195 mm x 101 mm x 50 mm Weight 300...

Страница 9: ...g Precision 16 mg 32 mg 64 mg 192 mg Bluetooth Compatibility BLE base on Bluetooth 5 BLE Sensitivity 0 1 BER 125 kbps 103 dBm 500 kbps 98 dBm 2 Mbps 91 dBm Temperature Measurement Accuracy 1 C between...

Страница 10: ...significant damage to TEKTELIC Unpacking should be conducted in a clean and dry location Do not discard the shipping box or inserts as they will be required if a unit is returned for repair or re con...

Страница 11: ...cause the Tracker to go to DEEP SLEEP As soon as new batteries are inserted the Tracker boots up and tries to join a LoRaWAN 2 5 Mounting On either side of the enclosure there are two mounting holes...

Страница 12: ...replacement batteries include Tadiran TL 4930 S or TL 5930 S Xeno Energy XL 205F STD Saft LS33600 Once the Tracker is powered and tries to join see Section 3 3 for LED behavior replace the cover and...

Страница 13: ...oot and join process Both LEDs will come on briefly when power is first applied After a small delay 1 second the LEDs will turn off and one of them will blink briefly o If the System green LED blinks...

Страница 14: ...e batteries To completely power off the Tracker Open up the Tracker and remove the batteries To put the Tracker to DEEP SLEEP Open up the Tracker then press the reset button on the PCBA To awaken the...

Страница 15: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 16: ...ence L exploitation est autoris e aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage 2 L appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage es...

Страница 17: ...r User Guide T0006279_UG Version 1 1 TEKTELIC Communications Inc Confidential Page 17 of 17 References 1 LoRa Alliance LoRaWAN Specification ver 1 0 2 July 2016 2 LoRa Alliance LoRaWAN 1 0 2 Regional...