![Teknion Complements Series Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/teknion/complements-series/complements-series_installation-manuals_1076846064.webp)
Section:
Description:
Page No:
Date:
IMPORTANT: READ INSTRUCTIONS BEFORE OPERATING TABLE
Sept 2017
1 of 1
COM_111c
HOW TO ADJUST THE TABLE USING LOGIC DATA
HEIGHT ADJUSTABLE TABLES (LIVELLO)
GENERAL OPERATION:
Press and hold the DOWN or UP
button to move the table to the desired location.
MEMORY POSITIONS:
1. Move the Desk to the position you want to store. Display reads the
actual height of the desk (ex. 30").
2. Press the S button. The display reads S_.
3. Press the position button. of the choice (eg. 2). Display readsS2.
4. Now the height is stored on the chosen position button. The saving
operation is confirmed with a double-click sound and after approximately
2 seconds the stored height will be displayed.
* To move to desired positions saved in memory, press and hold the desired
position button. (1, 2, 3 or 4 as desired) The table automatically moves and
stops at chosen pre-set height..
* Any or all of the stored memory heights can be changed at anytime by
following steps 1-4.
Initialize Procedure:
When you are using the table for the first time, you must INITIALIZE the table legs.
x
Adjust the table to the lowest position and release the switch.
x
Press and hold the DOWN button for 10 seconds. The legs should move up and down a small distance to indicate that the command has been received.
x
Adjust the table to the highest position and back down to the lowest position
twice
in order to establish the full range of the table.
The table is now ready for normal use.
Troubleshooting:
x
If the table legs become un-level, you must RE-INTIALIZE the system as described above.
x
Ensure there are no obstructions in either the up or down direction.
x
If the legs are not operating properly, it may be necessary to press the DOWN button twice to start the initialization process.
x
If the display shows E01, you must RE-INITIALIZE the system. If you see other E## codes, contact your facilities representative for assistance.
Monthly Maintenance:
x
It is recommended that the table be RE-INITIALIZED once every month.