TD-1/07-008
64 / 83
To see value
:
LED
50 08 (wait)
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
CMS 2 FORMAT (wait)
To change value
:
LED
50 08 F
√
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
CMS 1 FORMAT
[FORMAT] √
(Select using B(left) and C(right) buttons)
F = CMS format type, 0 ~ 1
Default Value
: 0, Contact ID
To set CMS-2 contact as Contact ID do 50 08
0
√
o
DTMF 4+2, 4+1, 3+2, 3+1 Format Settings
Defines details of communication format of Central Monitoring Sta
tion if “1” is entered in 50 07-08.
1. option
Account No
Digit
2. option
Message Code
Digit
3. option
Communication
Frequency
ON
3
1
20 Baud
OFF
4
2
10 Baud
CMS-1
Address= 50 09
< IP >
To see value
:
LED
50 09 (wait)
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
09- CMS 1 SETTINGS (wait)
To change value
:
LED
50 09 F F F
√
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
09- CMS 1 SETTINGS
F F F √
FFF = Multiple choice selection (1,2,3)
Default Value
: 1=OFF, 2=OFF, 3=OFF
Example
: To set format as 4+1 do
“ 50 09 1(OFF)
2(ON)
√ “
CMS-2
Address= 50 10
< IP >
To see value :
LED
50 10 (wait)
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
10- CMS 2 SETTINGS (wait)
To change value
:
LED
50 10 F F F
√
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
10-CMS 2 SETTINGS
F F F √
F F F = Multiple choice selection (1,2,3)
Default Value
: 1=OFF, 2=OFF, 3=OFF
Example
: To set format as 3+2 do
50 10 1(ON)
2(OFF)
√
o
CMS Selection that Messages will be Sent
This setting defines which events will be sent to which CMS. Arm/Disarm, alarms, bypass events, zon
troubles are called related to their partitions.
Not
e: Keypad alarms(Panic, Fire, Duress, Tamper) aren’t belong to any partition.
Meanings of Options in this address are in the following;
1.option = CMS-1
2.option = CMS-2