TD-1/07-008
31 / 83
Dialer Settings
Redialing Pause
CMS-1 Communication
Format
CMS-2 Communication
Format
Address
50 06
50 07
50 08
Value
3 seconds
Contact ID
Contact ID
CMS Messages
Out of Partition
A Partition
B Partition
C
Partition
D Partition
CMS that
messages
will be
sent
Address
50 11
50 12
50 13
50 14
50 15
Value
CMS-1
CMS-1
CMS-1
CMS-1
CMS-1
OPTIONAL MODULE SETTINGS
Remote Control Module
Zone Expansion Module
Enable/Disable
Siren Alarm
on Panic
Enable/Disable
Address
1.opt.(60 01)
2.opt.(60 01)
1.opt.(61 01)
Value
OFF = Disable
OFF
OFF = Disable
Note1.
Indication of the days is 1.Monday, 2.Tuesday, 3.Wednesday, 4.Thursday, 5.Friday, 6.Saturday, 7.Sunday
Note2.
“Disable” sometimes means ‘closed’ or ‘NO’ ; “Enable” sometimes means ‘open’ or ‘NC’.
Note3.
Keypad settings are stored in Keypad not in Panel.
Note4.
4+2 codes are not defaulted. If 4+2 will be used, necessary codes should be entered manually.
6. LOADING FACTORY DEFAULTS
Panel has two types of returning factory defaults.
o
Loading default Codes ( from Installer or Master Program)
o
Loading default Panel Settings ( only from Installer Program)
Firstly, ensure that reset permissions are enabled and select reset type then activate reset.
Do jumper setting as following table to restore Panel Settings factory defaults. You don’t need change
jumper setting to restore codes to factory defaults.
RESTORING CODES TO FACTORY DEFAULTS
Firstly, ensure that reset code permission is enabled installer program(It is selected as a default). Make
following steps to reset codes.
4 (long) 9 9 9 9 (Enter Installer Program. Default installer code is 9 9 9 9 ).
LED Keypad
10 06 1(ON) √ ( This step isn’t needed to be done if default setting isn’t changed)
10 04 1(ON) √