TD-1/07-008
55 / 83
o
Type of Zone2
Address = 22 02
< IP >
Default Value
: 03 = Interior
o
Type of Zone4
Address = 22 04
< IP >
Default Value
: 03 = Interior
o
Type of Zone5
Zone8
Address = 22 05-08
< IP >
Default Value
: 03 = Interior
8.3.4 Zone Extra Settings
Meanings of options in installer address of 23 0X (X=Zone Number) is in the following. To activate option,
light corresponded led.
1.option
2.option
3.option
4.option
5.option
ON
End Door Follower(1) Entery/Exit(1) Silent Zone Can not be bypassed manually
OFF
Normal Normal
Normal
Normal
Can be bypassed manually
6.option 7.option
ON
Can not be bypassed automatically Cross Zone Enable(2)
OFF
Can be bypassed automatically Cross Zone Disable
If End door option is selected, Exit delay ends automatically when exit door is closed. Follower zone
provides delay time if firstly Enter/Exit zone is activated. If follower zone is activated firstly (before enter/exit
zone), panel alarms. Zone that users use to enter/exit area is set as Follower zone. If zone set as silent,
siren doesn’t alarm but communicator sends alarm code to Central Monitoring Station, when that zone is
activated. If 5.option is selected, that zone can’t be bypassed manually by using keypad. When 6.option is
not selected, that zone is bypassed automatically if that zone belongs to automatic bypassed partitions(Look
at page 44). Bypass is cancelled when zone returns to normal position in automatic bypass. If 7. option is
selected, zone is enable for cross zoning. Two or more trips specified as cross zone(s) that are on the same
partition are required for alarm within specified time in Cross zone timer. If Double Hit Feature is enabled,
two alarms from the same or different cross zone that is on the same partition within Cross zone timer cause
an alarm. “Intrusion verifier” code is sent to Central Monitoring Station(3) if an alarm is from cross zones.
“Cross Zone Fault” code is sent to Central Monitoring Station(3) if no any other violation after first trip on
cross zones that are on the same partition occurs within Cross zone timer duration.
Note(1) : 2. a
nd 3. option can’t be selected together.
(2)
: Cross zone feture only applies to zones defined as Door, Window, Interior, Exterior. It is not
recommended to enable Cross Zone feature on Entery/Exit and Follower zones.
(3)
: Don’t forget that codes can be sent to Central Monitoring Station if it is not disabled by installer.
o
Zone1
Address = 23 01
< IP >
To see value
:
LED
23 01 (wait)
LCD
2-ZONE SETTINGS
→ EXTRA SETTINGS → 01-ZONE OPTIONS (wait)
To change value
:
LED
23 01 S ........S √
LCD
2-
ZONE SETTINGS → EXTRA SETTINGS → 01-ZONE OPTIONS
S........S √
S= option(ON/OFF)
Default Value
: 3 = ON
Example
: To set 1.zone as End door do
“ 23 01 1(ON) √ “
o
Zone2
Address = 23 02
< IP >
Default Value
: -
.
.
.
.
o
Zone4
Address = 23 04
< IP >