RELEASE DATE
9-13-17
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
DRAWING
NUMBER
INS-2656-00
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Junction Box Integral Driver Installation
POWER PIPE II™ SYSTEM
Installation
5. Connect conduit to the 3/4” conduit couplers
attached to the bottom of the Power Pipe II™.
Place Power Pipe II™ in hole.
6. Back fill hole with soil and/or prep for concrete.
7. Pull branch circuit wiring necessary for
installation (By Others).
4. Excavate trench according to designed lighting
plan. Dig hole a minimum of 24” deep and 10” wide
to accommodate Power Pipe II™ at desired fixture
locations.
Finished grade
Pea gravel or sand
Concrete or Dirt
Finished grade
Finished grade
Pea gravel or sand
Concrete or Dirt
Finished grade
Finished grade
Pea gravel or sand
Concrete or Dirt
Finished grade
WIRING DIAGRAM
120V
COM
GROUND
WIRING DIAGRAM
Driver
GROUND FROM FIXTURE
120V
+
Fixture
COM
GROUND
Driver
-
GROUND IN T-HOUSING
120V
COM
All line voltage connections must be made
in accordance to NEC standards.
9. Insert wires and connectors into Power Pipe™.
Place fixture and cap on Power Pipe™.
10. Tighten three (3) Phillips screws using a Phillips
screwdriver.
8. Make waterproof connections from branch
circuit wiring to integral driver primary
side using waterproof wire connectors.
Connect incoming ground wire to
green fixture wire.
See wiring diagram.
1. Determine Soil Type by referencing DIG-IT Guide.
Prep soil according to DIG-IT Guide.
Conduit
trench
2. Dig hole 10” wide and 18” deep.
Conduit
Trench
Excavated
for Housing
3. Prep soil according to DIG-IT Guide.
Failure to use waterproof wire connectors
will cause fixture to fail and VOID PRODUCT
WARRANTY.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]